Specifications 

0

0

5

0

0

6

0

0

 

8

0

0

 

1000 

1200 

1500 

2000 

Electrical 

Output

 

Power 

400VA / 

24 0 W

 

500VA / 

300W

 

600VA / 

360W

 

800VA / 

480W

 

1000VA / 

800W

 

1200VA / 

720W

 

1500VA / 

900W

 

2000VA / 

1200W

 

lnput

 

Voltage

(VAC) 

100 / 110 / 115 / 120 / 220 / 230 / 240  ± 25%  at the unit's input.

 

lnput

 

Frequency

(z) 

50 / 60  ± 10%  (Unit has auto frequency sensing)

 

Output

 

Voltage

(VAC)

Backup mode

 

Simulated sine wave voltage 100 / 110 / 115 / 120 / 220 / 230 / 240 ±5%.

 

Output

Frequency

 

(z)

Backup mode

 

50 / 60  ± 1%

 

Voltage

Regulation

 

(AVR

)

 

AVR automatically increases the input voltage by 15%  if the line is -9%  to -25%  of nominal.

 

AVR decreases the input voltage by 13%  if the line is +9%  to +25%  of nominal.

 

Transfer

 

Time

(mSec) 

2 to 4, including detection time.

 

Safety 

UL, CSA, CE

 

Protection 

Spike

 

Protection 

480  Joules, 2 mSec

 

lnput 

Fuse or circuit breaker

 

Overload 

Automatic power off if overload exceeds 110%  of nominal for 60 seconds or 130% 

for 3 seconds.

 

Short

 

Circuit 

Automatic power off or input fuse protection.

 

Battery 

Type 

Sealed, maintenance free, lead-acid with 3 to 6 years typical lifetime.

 

Typical

Recharge

 

Time 

6 hours to 90%  of full capacity.

 

External

 

Battery

Option 

No

 

Yes

 

Protection 

Auto discharge protection.

 

Mechanical 

Dimensions

W

 

x

 

D

 

x

 

H ;

in

 

(mm) 

3.8 x 12.5 x 5.3 (9 x 320 x 135)

 

15 x 5.1 x 7.5 (382 x 130 x 192)

 

Weight

 

lbs

 

(kg) 

12.43 

(5.65)

 

14.17 

(6.44)

 

14.30 

(6.5)

 

14.52 

(6.6)

 

29.5 

(13.4)

 

29.5 

(13.4)

 

30.0 

(13.6)

 

32.0 

(14.5)

 

lnput

 

connector 

lEC 320 inlet

 

Output

Connectors 

NEMA 5-15R (115 V), lEC 320 female (220 V)

 

Page 

5

 to 

7

Summary of Contents for Tetrex 500

Page 1: ...Tetrex 500 USER MANUAL...

Page 2: ...outlined in this manual One at a time turn on the loads lf the buzzer is continuously on the unit is over loaded Turn off unnecessary loads To turn the unit off press the On Off button for more than...

Page 3: ...on the unit Green mode When green mode is on and the line becomes unqualified and less than 20 watts of power is drawn by the loads the unit automatically turns off When the line is requalified the u...

Page 4: ...t automatically turns itself off Disconnect unnecessary loads and restart the unit This alarm cannot be shut off Symptom Troubleshooting Table Causes Action Unit does not turn on the LED is not on The...

Page 5: ...Novell Netware and Linux Contact AOE for more information The software lets you Turn off the unit Set up an alarm when line power is unqualified Shut off power to the loads before the battery is drai...

Page 6: ...al Transfer Time mSec 2 to 4 including detection time Safety UL CSA CE Protection Spike Protection 480 Joules 2 mSec lnput Fuse or circuit breaker Overload Automatic power off if overload exceeds 110...

Page 7: ...00 1500 2000 Environment Altitude ft m 11 500 3500 Storage Altitude ft m 9 000 15 000 Humidity 0 to 95 non condensing Audible Noise 1 m 0 dBA Operating Temperature C F 0 0 32 10 Specifications subject...

Page 8: ...ed due to one of these causes or if the unit is free of defects a handling or repair fee may be assessed prior to returning the unit WITH RESPECT TO BATTERIES PERIPHERAL DEVICES ATTACHMENTS OR APPARAT...

Page 9: ...k energy com France and Benelux fbnl alpha outback energy com Spain spain alpha outback energy com Russia russia alpha outback energy com Africa africa alpha outback energy com Alpha and Outback Energ...

Reviews: