23
RDM Protocols
(2/3)
No.
Device Property
Value (Example)
Description
User Setting
Remarks
1
Device Model Description
L500
Model number of the device
Disable
2
Manufacturer Label
ALPHA LITE
Name of the manufacturer
Disable
3
Device Label
FOOT123
Fixture name and management
number
Enable
ex) Input :FOOT123
►
Name : FOOT123
►
Management # : 123
- Automatic recognition of up to 4 digits. If
there is no number, the default is '001'.
4
Software Version Label
M0E-v1.10-v5.27-180928
Software version
Disable
5
DMX Personality
1 Ch. Mode
DMX channel mode and color temperature
setting
Enable
See (Table 1)
6
DMX Start Address
1
DMX address
Enable
1~512 Range
7
Device Hours
N/A
N/A
Display only, no actual response.
8
Lamp Hours
N/A
N/A
Display only, no actual response.
9
Lamp State
N/A
N/A
Display only, no actual response.
10
Lamp On Mode
N/A
N/A
Display only, no actual response.
11
Display Invert
On
LCD screen display direction
Enable
►
Off : 0˚
►
On : 180˚
►
Auto : Current opposite direction
12
Identify Device
Off
Selected fixture blinking indication
Enable
►
Off : Deactivates blinking
►
On : Activates blinking
13
Speed Set
15
Dimming delay Setting
Enable
0~40 range
The larger the value,the slower the dimming.
14
Display Mode
0
Normal screen / Fixture ID screen
transitions
Enable
►
0 : Normal screen
►
1 : Fixture ID screen
15
Max. Temp
75
Fixture maximum temperature
display
Enable
Use for initialization if necessary