background image

12

Unlocking

Main Screen (Locked)

Fixture ID Screen (Locked)

When the fixture is turned on, the Smart Touch screen automatically locked.
To unlock the touch screen, touch the finger icon(       ) three times.
If you do not touch for 30 seconds, the lock is reset.

A

A

A

Summary of Contents for A Series

Page 1: ...LED LIGHTING FOR UHD BROADCASTING EST 2008 USER MANUAL BASE LIGHT A SERIES ...

Page 2: ...y chain on the product when installing and moving 4 Please install the signs below for people to bypass when install the product on high truss 5 The work should be done under the direction of approved specialist who is trained in safety and mechanical installations 6 The brightness and color temperature before and after aging may be different Safety Information WARNING ...

Page 3: ...en Instruction 13 Menu Tree 14 Main Screen by Mode Product Information 15 DMX Mode Channel Change Address Setup 16 User Mode Intensity ColorTemperature TintAdjust 17 Color Mode Custom order only 18 Extra Function Sleep Mode Function 19 Master Function 19 RDM Function 19 Dimming Speed Setup 19 Fixture ID Number Setup 20 Fixture Label Setup 20 Error Information Temperature Sensor 21 Network Connecti...

Page 4: ...y soft light distribution High efficiency and light saturation by using Micro diffusing lens and excellent photometric flatness 2900 6000K color temperature control function Support RDM network communication and various mode setting possible Smart touch control method makes it easy and convenient to check all information at a glance When the DMX signal is shorted the last signal is maintained Long...

Page 5: ...4 Fixture Exterior View Yoke Smart Touch LCD Screen Handle Connector Panel Fixed Knob ...

Page 6: ...5 Dimensions A1840 mm inch ...

Page 7: ...6 Dimensions A2440 mm inch ...

Page 8: ...7 Dimensions A2460 mm inch ...

Page 9: ...z Power Consumption 150W 200W 300W White Light CCT Full 2 900 6 000K VCT CRI 95 98 TLCI 95 98 Dimming 0 100 Continuous CCT Deviation 100K Control 5 PIN DMX In and Out Smart Touch LCD Controller RDM Option Wireless DMX512 Wireless RDM Remote Device Management Supported Ambient Temperature Operation 20 45 C IP Rating IP20 Estimated LED Lifetime Over 50 000 hours This specification data is based on t...

Page 10: ...9 Photometric Diagram A1840 A2440 A2460 320 505 788 138 210 310 76 112 164 47 70 104 ...

Page 11: ... be generated from the SMPS 3 If the operating voltage is out of the proper voltage range SMPS function may be degraded or damaged AC power at 100 240V 50 60Hz 1 POWER ON OFF SWITCH 2 POWER IN 3 POWER OUT 4 DMX IN 5 DMX OUT 6 USB PORT forFirmwareUpdate Do not connect USB without administrator s permission ...

Page 12: ...er lighting fixture If user uses a standard DMX controller the DMX output of the controller can connect directly to the DMX input of the first fixture in the DMX chain User must use an adapter cable for connect the DMX controller to other XLR output Connect the DMX output of the first lighitng fixture in DMX chain to the DMX input of the next fixture and connect one output to the input of the next...

Page 13: ... Locked Fixture ID Screen Locked When the fixture is turned on the Smart Touch screen automatically locked To unlock the touch screen touch the finger icon three times If you do not touch for 30 seconds the lock is reset A A A ...

Page 14: ...nt 8 Home Return to the main screen 9 DMX512 Mode Address Setup Set channel mode and DMX512 address 10 User Mode Setup Set Intensity CCT and Tint manually 11 ColorModeSetup Customorderonly Set RGB lighting color Saturation and Intensity 12 Setting Setting or changing the function of the equipment 13 Fixture ID Displays numbers for equipment management 14 Equipment Information Displays the help tha...

Page 15: ...xture ID Θ Information Basic equipment information Θ Rotate Θ Home Main screen Θ DMX512 Mode DMX mode select DMX address input Θ Information DMX channel value Θ User Mode Intensity setup Color temperature setup Tint setup Custom order only Θ Information Description of each function Θ Color Mode Custom order only RGB color setup Saturation setup White setup Θ Full screen Individual RGB setup and Pr...

Page 16: ...and fixture temperature are displayed and some lighting value can be adjusted on the main screen by touching the value User can check information such as manufacturer product model name firmware version UID number current temperature of equipment usage time of equipment LED usage time website manual download link etc by clicking the INFO button on the main screen Through each Menu INFO touch user ...

Page 17: ...ue To return to the previous screen press the Info button again Support channels and features vary by product User can move to the DMX channel change screen by selecting DMX512 MODE button in main screen In DMX512 MODE screen user can select DMX channel mode on top tap and input DMX512 address by pressing the number pad DMX MODE It is used to adjust by DMX512 signal ...

Page 18: ...t value USER MODE It is used when the user directly manipulates the equipment Intensity The number indicates the current brightness value of the fixture and is displayed from 0 to 100 CCT The number indicates the current color temperature value of the fixture and is displayed from 2 900 to 6 000K Tint The number indicates the current tint Gamma value of the fixture and is displayed from 1 00 Magen...

Page 19: ...djusting the desired value press Enter to return to the COLOR MODE screen Color Mode It is used when the user directly manipulates the equipment Color Wheel Gradient Touch or drag the color user want Hue Drag and select the Hue user want Saturation The number indicates the current saturation value of the fixture and is displayed from 0 to 100 White The number indicates the current White LED bright...

Page 20: ...tures without a console connection If Off the DMX signal will follow RDM setup Default On Set the feature that enables bi directional wireless communication through RDM equipment If Off this equipment will not be searched on RDM equipment Dimming speed setup The number indicates the current dimming speed value of the fixture and is displayed from 0 to 40 The higher the value the slower the dimming...

Page 21: ...vice is basically the model name and it can be changed through RDM communication but it can t be changed through the Smart Touch LCD When changing the label of the device through RDM enter the device name English and the management number in the Device Label field The entered contents are displayed in the upper left corner The fixture ID is automatically displayed in 3 or 4 digits from automatical...

Page 22: ...LED output will be 0 and Temperature Error Please Check Device will be displayed The error messages are only displayed on the main screen and the fixture ID screen Even if the temperature falls to the normal range It does not disappear In this case normalize the temperature of the equipment and restart it Temperature Sensor When the DMX512 network connection is lost the DMX512 address number in ma...

Page 23: ... CCT 3 0 119 120 255 See DMX Protocols 3 Tint 5 1 0 255 0 100 Dimmer 2 0 255 0 100 Color Temperature CCT 3 0 119 120 255 See DMX Protocols 3 Tint 4 0 255 0 100 Cross Fader 5 0 255 0 100 Color Macro 8 1 0 255 0 100 Dimmer 2 0 255 0 100 Color Temperature CCT 3 0 119 120 255 See DMX Protocols 3 Tint 4 0 255 0 100 Cross Fader 5 0 255 0 100 Red 6 0 255 0 100 Green 7 0 255 0 100 Blue 8 0 255 0 100 White...

Page 24: ... 5150K 184 187 5200K 188 191 5250K 192 195 5300K 196 199 5350K 200 203 5400K 204 207 5450K 208 211 5500K 212 215 5550K 216 219 5600K 220 223 5650K 224 227 5700K 228 231 5750K 232 235 5800K 236 239 5850K 240 243 5900K 244 247 5950K 248 255 6000K DMX Value Function 88 91 4000K 92 95 4050K 96 99 4100K 100 103 4150K 104 107 4200K 108 111 4250K 112 115 4300K 116 119 4350K 120 123 4400K 124 127 4450K 12...

Page 25: ...alue Function 3 0 10 0 No Effect 11 20 1 00 Full Magenta 21 119 0 99 0 01 99 1 Magenta 120 145 0 No Effect 146 244 0 01 0 99 1 99 Green 245 255 1 00 Full Green DMX Protocols 3 3 Channel 3 Tint Custom RGB added model Tint channel ...

Page 26: ...L YES YES SENSOR_DEFINITION YES SENSOR_VALUE YES DMX_PERSONALITY YES YES DMX_PERSONALITY_DESCRIPTION YES STATUS_MESSAGES YES Lamp Controls No Control Property Value Example Description UserSettings Remarks 1 Identify On N A Device identification action active Enable Identify device Same as On 2 Identify Off N A Device identification action inactive Enable Identify device Same as Off 3 Cold Reset N...

Page 27: ... address Enable 1 512 Range 7 Device Hours N A N A Display only no actual response 8 Lamp Hours N A N A Display only no actual response 9 Lamp State N A N A Display only no actual response 10 Lamp On Mode N A N A Display only no actual response 11 Display Invert On LCD screen display direction Enable Off 0 On 180 Auto Current opposite direction 12 Identify Device Off Selected fixture blinking indi...

Page 28: ...00K Color Temperature 1 Ch 3000K 1 Ch Mode 3000K Color Temperature 1 Ch 3100K 1 Ch Mode 3100K Color Temperature 1 Ch 3200K 1 Ch Mode 3200K Color Temperature 1 Ch 4400K 1 Ch Mode 4400K Color Temperature 1 Ch 4500K 1 Ch Mode 4500K Color Temperature 1 Ch 5500K 1 Ch Mode 5500K Color Temperature 1 Ch 5600K 1 Ch Mode 5600K Color Temperature 1 Ch 5700K 1 Ch Mode 5700K Color Temperature 1 Ch 6000K 1 Ch Mo...

Page 29: ......

Reviews: