3 & 5 & 8 Channel mode : Color Temperature

DMX 

Value

Function

0~1

2500

2~3

2550

4~5

2600

6

2650

7~8

2700

9~10

2750

11

2800

12~13

2850

14~15

2900

16

2950

17~18

3000

19~20

3050

21~22

3100

23

3150

24~25

3200

26~27

3250

28

3300

29~30

3350

31~32

3400

33

3450

34~35

3500

36~37

3550

38~39

3600

40

3650

41~42

3700

43~44

3750

45

3800

46~47

3850

48~49

3900

50

3950

DMX 

Value

Function

51~52

4000

53~54

4050

55~56

4100

57

4150

58~59

4200

60~61

4250

62

4300

63~64

4350

65~66

4400

67

4450

68~69

4500

70~71

4550

72~73

4600

74

4650

75~76

4700

77~78

4750

79

4800

80~81

4850

82~83

4900

84

4950

85~86

5000

87~88

5050

89~90

5100

91

5150

92~93

5200

94~95

5250

96

5300

97~98

5350

99~100

5400

101

5450

DMX 

Value

Function

102~103

5500

104~105

5550

106~107

5600

108

5650

109~110

5700

111~112

5750

113

5800

114~115

5850

116~117

5900

118

5950

119~120

6000

121~122

6050

123~124

6100

125

6150

126~127

6200

128~129

6250

130

6300

131~132

6350

133~134

6400

135

6450

136~137

6500

138~139

6550

140~141

6600

142

6650

143~144

6700

145~146

6750

147

6800

148~149

6850

150~151

6900

152

6950

DMX 

Value

Function

153~154

5500

155~156

5550

157~158

5600

159

5650

160~161

5700

162~163

5750

164

5800

165~166

5850

167~168

5900

169

5950

170~171

6000

172~173

6050

174~1v75

6100

176

6150

177~178

6200

179~180

6250

181

6300

182~183

6350

184~185

6400

186

6450

187~188

6500

189~190

6550

191~192

6600

193

6650

194~195

6700

196~197

6750

198

6800

199~200

6850

201~202

6900

203

6950

DMX 

Value

Function

204~205

5500

206~207

5550

208~209

5600

210

5650

211~212

5700

213~214

5750

215

5800

216~217

5850

218~219

5900

220

5950

221~222

6000

223~224

6050

225~226

6100

227

6150

228~229

6200

230~231

6250

232

6300

233~234

6350

235~236

6400

237

6450

238~239

6500

240~241

6550

242~243

6600

244

6650

245~246

6700

247~248

6750

249

6800

250~251

6850

252~253

6900

254

6950

255

10000

Summary of Contents for A-Plus Series

Page 1: ...A 8 P LU S A 8 P LU S A P L U S S E R I E S ALPHA LITE ALPHA LITE USER MANUAL USER MANUAL BOOK BOOK ...

Page 2: ...rk Be sure to fix the safety chain on the product when installing and moving Please install the signs below for people to bypass when install the product on high truss The work should be done under the direction of approved specialist who is trained in safety and mechanical installations The brightness and color temperature before and after aging may be different 2 3 4 5 6 1 Precautions ...

Page 3: ...hite Adjust 11 12 13 14 15 16 17 LCD Screen Instruction Safety Information 1 Sleep Mode Function RDM Function Dimming Speed Setup Master Function Fixture ID Number Setup Device Label Setup 18 19 20 Extra Function Temperature Sensor Network Connection 21 Error Information Cross Fader Color Macro 22 Extra Information DMX Protocols RDM Protocols 23 26 Protocols Fixture Information Fixture Exterior Vi...

Page 4: ...ution High efficiency and light saturation by using Micro diffusing lens and excellent photometric flatness 2500 10000K color temperature control function R G B Full Color LEDs are combined to create a scene for all acting parts and a variety of atmospheres Support RDM network communication and various mode setting possible Smart touch control method makes it easy and convenient to check all infor...

Page 5: ...4 ALPHA LITE USER MANUAL BOOK Fixture Exterior View Fixed Knob Yoke Clamp Barndoor Connector Panel Smart Touch LCD Screen Handle ...

Page 6: ...5 Product name A8 PLUS Dimensions ...

Page 7: ...6 ALPHA LITE USER MANUAL BOOK Pole operation yoke Pan Tilt Soft box Detachable Honeycomb Detachable Accessory Options ...

Page 8: ... Optional Supported Protocol DMX512 Wireless RDM Wireless Remote Device Management Supported Channel Function Dimming CCT Tint RGBW Cross Fader Color Macro Power Input Voltage AC 100 240V 50 60Hz Power Consumption W 400 Ambient Temperature Operation C 20 45 Spigot Mounting mm 16 28 Tilt Angle 90 Body Dimensions mm inch WHD 685 x 320 x 170 27 x 12 6 x 6 7 Full Dimensions with Manual Yoke mm inch WH...

Page 9: ...8 ALPHA LITE USER MANUAL BOOK 0m 1m 3m 5m 7m 9m 135 1040 402 213 136 5600K 5600K Photometry Data Distance m Illuminance lux ...

Page 10: ... proper voltage rang 2 If power is supplied outside the range noise may be generated from the SMPS 3 If the operating voltage is out of the proper voltage range SMPS function may be degraded or damaged WARNING Power Pass Thru Based on operating voltage 240V and using the cable provided by ALPHA LITE IN OUT IN OUT IN OUT IN OUT IN OUT Connect 01 Start connection Connect 02 Connect 03 Max Connect 8 ...

Page 11: ...st use an adapter cable for connect the DMX controller to other XLR output Shield Signal Signal Not Connected Not Connected Shield Signal Signal Not Connected Not Connected DMX INPUT XLR Mounting plugs DMX OUTPUT XLR Mounting sockets 1 Connect the DMX output of the first lighitng fixture in DMX chain to the DMX input of the next fixture 2 Connect one output to the input of the next fixture until a...

Page 12: ...the fixture is turned on the Smart Touch screen automatically locked To unlock the touch screen touch the finger icon three times If you do not touch for 30 seconds the lock is reset Main Screen Locked Fixture ID Screen Locked A A A x 3 x 3 ...

Page 13: ...Adjust the selected function among Intensity Color Temperature and Tint In DMX MODE Current channel mode Display current channel mode Only display on DMX MODE 08 Home Return to the main screen 09 DMX512 Mode Address Setup Set channel mode and DMX512 address 10 User Mode Setup Set Intensity CCT and Tint manually 11 Color Mode Setup Set RGB lighting color Saturation and Intensity 12 Setting Setting ...

Page 14: ...nformation DMX address input Color temperature setup Saturation setup Master function setup Information Tint setup White setup RDM mode setup DMX channel value Description of each function Individual RGB setup and Preset RGBW value Description of each function Description of fixture ID Information Full screen Dimming speed setup Information Information Fixture ID number input Information Home Main...

Page 15: ...n the middle with a yellow number At the bottom the current lighting value and fixture temperature are displayed and some lighting value can be adjusted on the main screen by touching the value DMX MODE USER MODE COLOR MODE HOME DMX MODE USER MODE COLOR MODE INFO Product model name firmware version UID number current temperature of equipment usage time of equipment LED usage time website manual do...

Page 16: ... Ch Mode Dimming CCT 5 5 Ch Mode Dimming CCT Tint Cross Fader Color Macro 8 8 Ch Mode Dimming CCT Tint Cross Fader Red Green Blue White Support channels and features vary by product information DMX MODE It is used to adjust value by DMX512 signal DMX512 MODE HOME Move to the DMX channel change screen In DMX512 MODE screen user can select DMX channel mode on top tap Input DMX512 address by pressing...

Page 17: ...touch or drag Drag the activated bar close to the desired value and then touch to set the exact value Activate control bar and adjust value directly according to selected function To return to the previous screen press the INFO button again Intensity The number indicates the current brightness value of the fixture and is displayed from 0 to 100 CCT The number indicates the current color temperatur...

Page 18: ...d is displayed from 0 to 100 White The number indicates the current White LED brightness value of the fixture and is displayed from 0 to 100 information COLOR MODE COLOR MODE It is used when the user directly manipulates the equipment COLOR MODE screen Touch the function you want to change Active in Orange Adjust the value with touch or drag Individual RGB value adjustment and saving preset 1 9 ca...

Page 19: ...Sleep mode setup Default Off The function to automatically turn off the screen when there is no operation for 30 seconds If OFF it is always on the screen while power is on Master setup Default Off The function to synchronize and user control all connected fixtures without a console connection If OFF the DMX signal will follow RDM setup Default On The function to enable two way wireless communicat...

Page 20: ...Setup The master slave function allows to synchronize and control all connected lighting fixtures through the DMX signal without a console connection If a problem occurs in the console or communication line it is possible to control the brightness and CCT and color with only the lighting fixture Main screen Setting Touch MASTER SETUP the function turns on 2 Touch Functions available with one setti...

Page 21: ... press Enter Move to the FIXTURE ID screen that displays the large size entered value Touch HOME icon to go back to the main screen The fixture ID is displayed in 3 or 4 digits from automatically recognized 4 digits in contents If user do not enter any number the fixture ID is displayed as 001 Main Screen Fixture ID Screen Fixture ID Input Screen It is the number value 001 to 9999 for the manageme...

Page 22: ...ase Check Device will be displayed The error messages are only displayed on the main screen and the fixture ID screen Even if the temperature falls to the normal range It does not disappear In this case normalize the temperature of the equipment and restart it Detects the temperature of the current fixture LED source housing and displays it on the Smart Touch LCD screen When the DMX512 network con...

Page 23: ...lue and White in 8 Channel Mode is distributed As the DMX value of Ch 4 increase the brightness of Ch 2 decrease and the brightness of the color set by Ch 5 or Ch 5 8 increase at the same time The DMX value of Ch 4 adjusts the CCT and color brightness and density ratio relative to each other Cross Fader Color Macro 100 0 0 255 Cross Fader Value Bright Value Color Macro Ch 5 in 5 channel mode is ra...

Page 24: ... 100 Blue 8 0 255 0 100 White Mode Channel DMX Value Function 5 1 0 255 0 100 Dimmer 2 0 255 0 100 Color Temperature CCT 3 0 119 120 255 See DMX Protocols 3 Tint 4 0 255 0 100 Cross Fader 5 0 255 0 100 Color Macro Mode Channel DMX Value Function 3 1 0 255 0 100 Dimmer 2 0 255 0 100 Color Temperature CCT 3 0 119 120 255 See DMX Protocols 3 Tint Mode Channel DMX Value Function 1 1 0 255 0 100 Dimmer...

Page 25: ...14 115 5850 116 117 5900 118 5950 119 120 6000 121 122 6050 123 124 6100 125 6150 126 127 6200 128 129 6250 130 6300 131 132 6350 133 134 6400 135 6450 136 137 6500 138 139 6550 140 141 6600 142 6650 143 144 6700 145 146 6750 147 6800 148 149 6850 150 151 6900 152 6950 DMX Value Function 153 154 5500 155 156 5550 157 158 5600 159 5650 160 161 5700 162 163 5750 164 5800 165 166 5850 167 168 5900 16...

Page 26: ... 102 103 106 107 110 111 114 115 118 119 122 123 126 127 130 DMX Value Color Value Color Macro 131 134 135 138 139 142 143 146 147 150 151 154 155 158 159 162 163 166 167 170 171 174 175 178 179 182 183 186 187 190 191 194 195 198 199 202 203 206 207 210 211 214 215 218 219 222 223 226 227 230 231 234 235 238 239 242 243 246 247 250 251 255 DMX Protocols 3 4 3 5 8 Channel Mode Color Macro ...

Page 27: ...ICE YES YES DEVICE_MODEL_DESCRIPTION YES MANUFACTURER_LABEL YES DEVICE_LABEL YES YES SENSOR_DEFINITION YES SENSOR_VALUE YES DMX_PERSONALITY YES YES DMX_PERSONALITY_DESCRIPTION YES STATUS_MESSAGES YES Tint Mode DMX Value Output Value Function 3 0 10 0 No Effect 11 20 1 00 Full Magenta 21 119 0 99 0 01 99 1 Magenta 120 145 0 No Effect 146 244 0 01 0 99 1 99 Green 245 255 1 00 Full Green RDM Protocol...

Page 28: ...here is no number the default is 001 4 Software Version Label M0E v1 10 v5 27 180928 Software version Disable 5 DMX Personality 1 Ch Mode DMX channel mode and color temperature setting Enable See Table 1 6 DMX Start Address 1 DMX address Enable 1 512 Range 7 Device Hours N A N A Display only no actual response 8 Lamp Hours N A N A Display only no actual response 9 Lamp State N A N A Display only n...

Page 29: ...cription 8 Ch Model Device Variable Color Temperature RGB 1 Ch Mode 1 Ch Mode 3 Ch Mode 3 Ch Mode 5 Ch Mode 5 Ch Mode 8 Ch Mode 8 Ch Mode 1 Ch 2500K 1 Ch Mode 2500K Color Temperature 1 Ch 2900K 1 Ch Mode 2900K Color Temperature 1 Ch 3000K 1 Ch Mode 3000K Color Temperature 1 Ch 3500K 1 Ch Mode 3500K Color Temperature 1 Ch 4000K 1 Ch Mode 4000K Color Temperature 1 Ch 4500K 1 Ch Mode 4500K Color Temp...

Page 30: ... Tel 82 2 6317 0464 Fax 82 2 2039 0464 E mail hello alpha lite net Web www alpha lite net 2 4 Floor 5 8 Gyeongin ro 88 gil Yeongdeungpo gu Seoul Republic of Korea 07363 ALPHA LITE USER MANUAL BOOK ...

Reviews: