background image

29

Product name.

ALPHA 3060

DMX Value

Channel

0

Neutral / No effect

1~255

1 / Slow ~ 255 / Fast

 

No

Control Property

Value 

(Example)

Description

User Setting

Remarks

1

Identify On

N/A

Device identification action 

active

Enable

Identify device = Same as On

2

Identify Off

N/A

Device identification action 

inactive

Enable

Identify device = Same as Off

3

Cold Reset

N/A

Device reset(restart)

Enable

Same as Warm reset

4

Warm Reset

N/A

Device reset(restart)

Enable

Same as Cold reset

[ Lamp Controls ]

RDM Protocols (2/3)

No

Device Property

Value 

(Example)

Description

User 

Setting

Remarks

1

Device Model Description

ALPHA 3060

Model number 

of the device

Disable

2

Manufacturer Label

ALPHA LITE

Name of the 

manufacturer

Disable

3

Device Label

BASE123

Fixture name and 

management number

Enable

ex) Input : BASE123

· Name : BASE123

· Management # : 123

- Automatic recognition of 

up to 4 digits. If there is 

no number, the default 

is '001'.

4

Software Version Label

M0E-v1.10-

v5.27-180928

Software version

Disable

5

DMX Personality

1 Ch. Mode

DMX channel mode 

and color temperature 

setting

Enable

See (Table 1)

6

DMX Start Address

1

DMX address

Enable

1~512 Range

7

Device Hours

N/A

N/A

Display only, no actual response.

8

Lamp Hours

N/A

N/A

Display only, no actual response.

9

Lamp State

N/A

N/A

Display only, no actual response.

10

Lamp On Mode

N/A

N/A

Display only, no actual response.

11

Display Invert

On

LCD screen display 

direction

Enable

· Off : 0˚

· On : 180˚

· Auto : Current opposite 

direction

12

Identify Device

Off

Selected fixture blinking 

indication

Enable

· Off : Deactivates blinking 

· On : Activates blinking

13

Speed Set

15

Dimming delay Setting

Enable

0~40 range

The larger the value, the slower 

the dimming.

14

Display Mode

0

Normal screen / Fixture 

ID screen transitions

Enable

· 0 : Normal screen

· 1 : Fixture ID screen

15

Max. Temp

75

Fixture maximum 

temperature display

Enable

Use for initialization if necessary

Summary of Contents for 3045

Page 1: ...A L P H A 3 0 6 0 A L P H A 3 0 6 0 A L P H A S E V E N C O L O R ALPHA LITE ALPHA LITE USER MANUAL USER MANUAL BOOK BOOK ...

Page 2: ...safety chain on the product when installing and moving Please install the signs below for people to bypass when install the product on high truss The work should be done under the direction of approved specialist who is trained in safety and mechanical installations The brightness and color temperature before and after aging may be different 2 3 4 5 6 1 Precautions Product name ALPHA 3060 ...

Page 3: ... 17 18 19 LCD Screen Instruction Safety Information 1 Sleep Mode Function RDM Function Dimming Speed Setup Master Function Fixture ID Number Setup Fixture Label Setup 20 21 22 Extra Function Temperature Sensor Network Connection 23 Error Information Cross Fader Color Macro 24 Extra Information DMX Protocols RDM Protocols 25 28 Protocols Fixture Information Fixture Exterior View Dimensions Accessor...

Page 4: ...neration of LED lighting with a new light source optical solution for lighting control and an innovative operation interface It is a package lighting composed of LED spot LED panel with 6 Color 2 White ultra high capacity LED engine and ALPHA LITE s unique α Algorithm Overcome the limits of the color expression gamut and color temperature range that existing White lighting and RGB lighting it beca...

Page 5: ...4 ALPHA LITE USER MANUAL BOOK Fixture Exterior View Fixed Knob Yoke Smart Touch LCD Screen Handle Connector Panel ...

Page 6: ...5 Product name ALPHA 3060 Dimensions ...

Page 7: ...6 ALPHA LITE USER MANUAL BOOK Accessory Options Pole operation yoke Pan Tilt Soft box Detachable Honeycomb Detachable ...

Page 8: ...tocol DMX512 RDM Optional Supported Protocol DMX512 Wireless RDM Wireless Remote Device Management Supported Channel Function Dimming CCT Tint RGBALC Cross Fader Color Macro Strobe Power Input Voltage AC 100 240V 50 60Hz Power Consumption W 450 Ambient Temperature Operation C 20 45 Spigot Mounting mm 16 28 Tilt Angle 90 Body Dimensions mm inch WHD 708 x 390 x 192 27 9 x 15 4 x 7 6 Full Dimensions ...

Page 9: ... 7m 9m Front side Micro Lens 115 1153 450 245 163 Flip Side Micro Lens 85 1537 560 291 178 5600K 5600K Lens System ALPHA 3045 ex Photometry Data Multi Array Lens Micro Beam Shaping Film Micro Diffuser Distance m Illuminance lux Illuminance lux ...

Page 10: ...sert the bottom of the Barndoor into the top groove of the body 1 3 2 4 Fit the bolt at the top of the Barndoor to the groove Lower the Barndoor down along the groove Turn the bolt clockwise to fix the Barn door Barndoor Assembly ...

Page 11: ...en replacing the diffuser lens insert the soft side facing inward The rough side is the front Pull the latch toward the back of the body Take out the diffuser lens on the left Replace the diffuser lens by pushing it sideways 3 2 1 When replacing the diffuser lens insert the soft side facing inward The rough side is the front ALPHA 3060 Image example Diffuser Lens Change ...

Page 12: ...TOR ONLY Do not connect USB without administrator s permission 1 Observe the proper voltage rang 2 If power is supplied outside the range noise may be generated from the SMPS 3 If the operating voltage is out of the proper voltage range SMPS function may be degraded or damaged WARNING IN OUT IN OUT IN OUT IN OUT IN OUT Connect 01 Start connection Connect 02 Connect 03 Max Connect 8 Connect 07 Reco...

Page 13: ...X chain User must use an adapter cable for connect the DMX controller to other XLR output Shield Signal Signal Not Connected Not Connected Shield Signal Signal Not Connected Not Connected DMX INPUT XLR Mounting plugs DMX OUTPUT XLR Mounting sockets 1 Connect the DMX output of the first lighitng fixture in DMX chain to the DMX input of the next fixture 2 Connect one output to the input of the next ...

Page 14: ...n the fixture is turned on the Smart Touch screen automatically locked To unlock the touch screen touch the finger icon three times If you do not touch for 30 seconds the lock is reset Main Screen Locked Fixture ID Screen Locked A A A x 3 x 3 ...

Page 15: ...Adjust the selected function among Intensity Color Temperature and Tint In DMX MODE Current channel mode Display current channel mode Only display on DMX MODE 08 Home Return to the main screen 09 DMX512 Mode Address Setup Set channel mode and DMX512 address 10 User Mode Setup Set Intensity CCT and Tint manually 11 Color Mode Setup Set RGB lighting color Saturation and Intensity 12 Setting Setting ...

Page 16: ...information DMX address input Color temperature setup Saturation setup Master function setup Information Tint setup White setup RDM mode setup DMX channel value Description of each function Individual RGB setup and Preset RGBW value Description of each function Description of fixture ID Information Full screen Dimming speed setup Information Information Fixture ID number input Information Home Mai...

Page 17: ... bottom the current lighting value and fixture temperature are displayed and some lighting value can be adjusted on the main screen by touching the value DMX MODE USER MODE COLOR MODE HOME DMX MODE USER MODE COLOR MODE INFO Product model name firmware version UID number current temperature of equipment usage time of equipment LED usage time website manual download link etc by clicking the INFO but...

Page 18: ...3 3 Ch Mode Dimming CCT 5 5 Ch Mode Dimming CCT Tint Cross Fader Color Macro 12 12 Ch Mode Dimming CCT Tint Cross Fader Red Green Blue Amber Lime Cyan Color Macro Strobe Support channels and features vary by product information DMX Mode Channel Change Address Setup DMX MODE It is used to adjust value by DMX512 signal In DMX512 MODE screen user can select DMX channel mode on top tap Input DMX512 ad...

Page 19: ...nt OR In DMX mode even if you press the current value on the main screen the bottom bar is not active Activate control bar and adjust value directly according to selected function To return to the previous screen press the INFO button again Intensity The number indicates the current brightness value of the fixture and is displayed from 0 to 100 CCT The number indicates the current color temperatur...

Page 20: ...and is displayed from 0 to 100 White The number indicates the current White LED brightness value of the fixture and is displayed from 0 to 100 information COLOR MODE COLOR MODE It is used when the user directly manipulates the equipment COLOR MODE screen Touch the function you want to change Active in Orange Adjust the value with touch or drag Individual RGB value adjustment and saving preset 1 9 ...

Page 21: ...Sleep mode setup Default Off The function to automatically turn off the screen when there is no operation for 30 seconds If OFF it is always on the screen while power is on Master setup Default Off The function to synchronize and user control all connected fixtures without a console connection If OFF the DMX signal will follow RDM setup Default On The function to enable two way wireless communicat...

Page 22: ...r Setup The master slave function allows to synchronize and control all connected lighting fixtures through the DMX signal without a console connection If a problem occurs in the console or communication line it is possible to control the brightness and CCT and color with only the lighting fixture Main screen Setting Touch MASTER SETUP the function turns on 2 Touch Functions available with one set...

Page 23: ...tered contents are displayed in the upper left corner Move to fixture management number setting screen FIXTURE ID HOME Move to input screen that can change the number Input the desired number 001 to 9999 and press Enter Move to the FIXTURE ID screen that displays the large size entered value Touch HOME icon to go back to the main screen The fixture ID is displayed in 3 or 4 digits from automatical...

Page 24: ...ease Check Device will be displayed The error messages are only displayed on the main screen and the fixture ID screen Even if the temperature falls to the normal range It does not disappear In this case normalize the temperature of the equipment and restart it Detects the temperature of the current fixture LED source housing and displays it on the Smart Touch LCD screen When the DMX512 network co...

Page 25: ...e the last set color among Ch 5 10 Individual color settings and Ch 11 Color Macro is applied and distributed As the DMX value of Ch 4 increase the brightness of Ch 2 decrease and the brightness of the color set by Ch 5 or Ch 5 11 increase at the same time The DMX value of Ch 4 adjusts the CCT and color brightness and density ratio relative to each other Cross Fader Color Macro 100 0 0 255 Cross F...

Page 26: ...100 Cyan 11 0 255 See DMX Protocols 4 Color Macro 12 0 255 Strobe Mode Channel DMX Value Function 5 1 0 255 0 100 Dimmer 2 0 255 See DMX Protocols 2 Color Temperature CCT 3 0 119 120 255 See DMX Protocols 3 Tint 4 0 255 0 100 Cross Fader 5 0 255 See DMX Protocols 4 Color Macro Mode Channel DMX Value Function 3 1 0 255 0 100 Dimmer 2 0 255 See DMX Protocols 2 Color Temperature CCT 3 0 119 120 255 S...

Page 27: ...6 5900 117 118 5950 119 120 6000 121 6050 122 123 6100 124 125 6150 126 6200 127 128 6250 129 130 6300 131 132 6350 133 6400 134 135 6450 136 137 6500 138 6600 139 140 6700 141 142 6800 143 6900 144 145 7000 146 147 7100 148 7200 149 150 7300 DMX Value Function 151 152 7400 153 7500 154 155 7600 156 157 7700 158 7800 159 160 7900 161 162 8000 163 164 8100 165 8200 166 167 8300 168 169 8400 170 850...

Page 28: ...9 102 103 106 107 110 111 114 115 118 119 122 123 126 127 130 DMX Value Color Value Color Macro 131 134 135 138 139 142 143 146 147 150 151 154 155 158 159 162 163 166 167 170 171 174 175 178 179 182 183 186 187 190 191 194 195 198 199 202 203 206 207 210 211 214 215 218 219 222 223 226 227 230 231 234 235 238 239 242 243 246 247 250 251 255 DMX Protocols 3 4 3 5 12 Channel Mode Color Macro ...

Page 29: ...rotocols 1 3 Parameter ID Discovery command SET command GET command DISC_UNIQUE_BRANCH YES DISC_MUTE YES DISC_UN_MUTE YES DEVICE_INFO YES SUPPORTED_PARAMETERS YES SOFTWARE_VERSION_LABEL YES DMX_START_ADDRESS YES YES IDENTIFY_DEVICE YES YES DEVICE_MODEL_DESCRIPTION YES MANUFACTURER_LABEL YES DEVICE_LABEL YES YES SENSOR_DEFINITION YES SENSOR_VALUE YES DMX_PERSONALITY YES YES DMX_PERSONALITY_DESCRIPT...

Page 30: ...f there is no number the default is 001 4 Software Version Label M0E v1 10 v5 27 180928 Software version Disable 5 DMX Personality 1 Ch Mode DMX channel mode and color temperature setting Enable See Table 1 6 DMX Start Address 1 DMX address Enable 1 512 Range 7 Device Hours N A N A Display only no actual response 8 Lamp Hours N A N A Display only no actual response 9 Lamp State N A N A Display onl...

Page 31: ... Color Temperature RGBALC 1 Ch Mode 1 Ch Mode 3 Ch Mode 3 Ch Mode 5 Ch Mode 5 Ch Mode 12 Ch Mode 12 Ch Mode 1 Ch 2000K 1 Ch Mode 2000K Color Temperature 1 Ch 2500K 1 Ch Mode 2500K Color Temperature 1 Ch 2900K 1 Ch Mode 2900K Color Temperature 1 Ch 3200K 1 Ch Mode 3200K Color Temperature 1 Ch 4000K 1 Ch Mode 4000K Color Temperature 1 Ch 5000K 1 Ch Mode 5000K Color Temperature 1 Ch 5600K 1 Ch Mode 5...

Page 32: ... Tel 82 2 6317 0464 Fax 82 2 2039 0464 E mail hello alpha lite net Web www alpha lite net 2 4 Floor 5 8 Gyeongin ro 88 gil Yeongdeungpo gu Seoul Republic of Korea 07363 ALPHA LITE USER MANUAL BOOK ...

Reviews: