POL
RU
S
FIN
DA
N
SWE
NOR
ENG
20
Operating modes and configuration
ENG
1. Press and hold the setting wheel (E) in order to open the configuration menu.
2. Select the symbol “
“ and confirm the selection by shortly pressing the setting
wheel.The following subordinate menu items are available in the menu, to be
accessed by turning the wheel:
“type”
for switching over the base station between the modes Heating and Cool-
ing.
(deactivated when multi-IO box is connected)
1. Turn the setting wheel (E) to “HEAT” for heating or “COOL” for cooling and
confirm by shortly pressing the wheel.
“Pr.nr”
for the selection of the week profile number (“no. 1, no. 2 ... no. 6”).
1. Select the number of the desired profile and confirm the selection by shortly
pressing the setting wheel.
“Pr.Ad”
for the individual setting of the week profiles („no. 1, no. 2 ... no. 6“). Up
to 6 heating phases (13 switch-over points) can be set in the week profile for every
week day for the selected heating profile. Programming is made for the selected
days for the time from 00:00 to 23:59 o’clock.
1. In the menu item “Pr.Ad”, select the number of the desired profile by turning
the setting wheel (E) and confirm the selection by shortly pressing the wheel.
2. Select the desired week day/working day/weekend/all days by turning the set-
ting wheel (E) and confirm the selection by shortly pressing the wheel.
3. Confirm the start time of 00:00 o’clock by shortly pressing the setting wheel (E).
4. Select the desired temperature for the starting time by turning/pressing and
confirm.
5. Select and confirm the time indicated in the display by turning/pressing the set-
ting wheel.
6. Select the desired temperature for the set period by turning/pressing and con-
firm.
7. Repeat the process for the complete period from 00:00 to 23:59 o’clock.