13
Subject to change without notice | 83056700fUK – Translation of the original operating manual | ait-deutschland GmbH
►
Unit
with
cooling,
14 kW capacity and higher
or
without
cooling:
►
Unit with cooling
up to 12 kW
capacity:
6. Disconnect the electrical connections:
►
Unit
up to 12 kW
capacity:
●
Disconnect 2 white connectors (1) at the bot-
tom of the electrical control cabinet. To do this,
release the lugs by pressing on the sides of
the connectors
● Pull out the black rectangular connector (2) at
the top of the module box
►
Unit
with 14 kW
capacity
and higher
:
●
Disconnect connector (1) at the bottom of the
electrical control cabinet
●
Disconnect connector (2) at the bottom of
the electrical control cabinet. To do this,
remove the control cabinet cover and undo the
connector from the inside
● Pull out the black rectangular connector (3) at
the top of the module box
NOTE
The following diagrams show the connec-
tions of units with up to 12 kW capacity. In
units with 14 kW capacity and higher all con
-
nections are installed with clips and without
valves.
7. Remove the insulation on the hydraulic connec-
tions.
8. Remove 3 clips on the hydraulic connections.