23
HT 6Split
HT 12Split
If the house has a cellar the stone caisson must be
positioned so that condensation water does not affect
the house. Otherwise the stone caisson can be posi-
tioned directly under the heat pump.
The outlet of the condensation water pipe must be at
frost free depth.
•
The outlet of the condensation water pipe must
be at frost free depth.
•
Route the pipe downward from the air/water heat
pump.
•
The condensation water pipe must have a water
seal to prevent air circulation in the pipe.
•
The installation length can be adjusted by the
size of the water seal.
Gutter drainage
IMPORTANT
Bend the hose to create a water seal, see illustration bel-
low.
LEK
Frostfritt
djup
Water seal
Frost free
depth
Water seal
LEK
From air/water heat
pump
CAUTION
If none of the recommended alternatives isused good
lead off of condensation water must be assured.
Chapter 5 |
Outdoor unit LSplit