TRANSPORT TO INSTALLATION LOCATION
Always comply with the following safety information
during transport:
WARNING!
Several people are required to transport
the unit. Take into account the weight of
the unit.
“Technical data
/
Scope of delivery” overview,
“General unit data” section,
CAUTION!
Wear safety gloves.
WARNING!
The unit can tilt and tip over when being
removed from the wooden pallet and dur-
ing transport. This can result in personal
injury and damage to the unit.
– Take suitable precautions to prevent
the risk of tipping over.
IMPORTANT
Never use components and hydraulic connec-
tions on the unit for transport purposes.
IMPORTANT
Do not tilt the unit more than a maximum of 45°
(in any direction).
To prevent transport damage, you should transport the
unit to its final place of installation in its packed condi-
tion (on the wooden pallet with packaging) using a pallet
truck.
If it is not possible to transport the unit to the final instal-
lation location using a pallet truck, you can also transport
the heat pump on a handcart.
Before transporting with a handcart, we recommend
removing the front panel in order to reduce the weight
of the unit.
Remove packaging and set extra box aside (will be
needed later on!)...
Remove angle bracket, transport and packaging
material from the unit…
Dispose of angle bracket, transport and packaging
material properly and in an ecologically compatible
way...
Lift unit from the pallet…
Remove front panel of unit...
•
To do so, loosen the quick-release screws. Turn
through 90° to the left…
•
Lift front panel and set aside in a safe place.
Push handcart under the rear side of the unit.
IMPORTANT
If the handcart is pushed under the unit at the
rear panel, ensure you do not damage any con-
nections during transport.
IMPORTANT
Transport with a handcart on the front side of
the unit is not permitted.
IMPORTANT
Do not tilt the unit more than a maximum of 45°
(in any direction).
INSTALLATION
CAUTION!
Several people are required to install the
unit.
NOTE.
Take into account the size of the unit.
“Technical data
/
Scope of delivery” overview,
“General unit data” section.
NOTE.
Always refer to and follow the installation plan
for the respective model. Note the size and
minimum clearances.
Installation plan for the respective model.