Alpes Inox F 2010 Series Instruction Manual Download Page 9

9

INSTALLATION

It is important that all the operations relative to the installation 
are performed by qualifi ed personnel.

Unpack the barbecue, removing all the wrapping and protect-
ing material. The kitchen unit that houses the built-in appliance 
must has the hole corresponding to the dimensions and position 
indicated. Before doing so, fi t the supplied packing strip. The 
barbecue is then fastened to the kitchen unit by tightening the 
special fasteners located underneath the unit.  Connect to mains 
by plugging the special power cord with die-casted three-pole 
connector into the power outlet, accessible to the user after 
installation has been completed. 
The appliance must be earthed. All electrical parts are 230 V 

~

 - 50 Hz. 

Our company is not liable for damages to people or things caused 
by the faulty or defi cient connection of the earthing line. 

We suggest that the barbecue should be placed underneath a 
suction hood or an exhaust/air cleaning system at a minimum 
distance of 60 cm and maximum 75 cm.

The degree of protection against fi re hazards of the appliance is 
of Y-type, therefore the latter can be drawn near to walls higher 
than the work top, with the single precaution of leaving a clear-
ance of approx. 18 cm on the side of the electric barbecue.

The base unit for the barbecue does not require any special 
structural feature for the insulation or aeration of the appliance. 
In case there is a horizontal partition between the bottom part 
of the barbecue cabinet and the unit underneath, leave a space 
of about 2 - 3 cm between the two surfaces.

Compact locking system with gradual closing applied on elec-
tronically welded supporting structure.

INSTALLATION

Il faut que toutes les opérations relatives à l’installation soient 
effectuées par du personnel qualifi é.

Déballer le barbecue en éliminant avec soin les matériaux divers 
servant de protection. L'appareil à encastrer devra être monté 
dans l'élément prévu qui devra être découpé aux dimensions 
indiquées. Avant d’effectuer l’encastrement, positionner le joint 
d’étanchéité fourni. Le blocage sur le meuble s’effectue en 
vissant les crochets prévus à cet effet et situés dans la partie au-
dessous de l'appareillage. Effectuer le branchement électrique en 
appliquant la fi che fourni au câble d'alimentation correspondant 
et l'introduire dans la prise de courant accessible à l'utilisateur 
une fois l'installation effectuée. Conformément aux normes en 
vigueur, il est obligatoire d’effectuer toujours une mise à la terre 
effi cace. Les parties électriques fonctionnent à une tension de 
230 V 

~

 - 50 Hz. 

Notre société décline toute responsabilité pour les éventuels 
dommages aux personnes et aux choses dérivant de l’absence 
de la mise à la terre ou d’une mise à la terre défectueuse. 

Il est opportun de placer le barbecue sous une cape aspirante-
épurante, à une distance minimum de 60 cm et maximum de 
75 cm.

Le degré de protection contre les risques d’incendie de l’appareil 
est de type Y, il peut donc être juxtaposé à des parois plus hautes 
par rapport au plan de travail, en n'oubliant pas de laisser une 
espace libre d'environ 18 cm du côté du barbecue électrique.

L’élément de base pour barbecue seulement n’a besoin d’aucune 
particularité de construction pour l’isolation ou l’aération de l’ap-
pareil. S’il existe un plan de séparation entre la partie inférieure 
du caisson du barbecue et le meuble situé en dessous, laisser un 
espace d’environ 2-3 cm entre les deux surfaces.

Le système de blocage est à fermeture progressive et d’encom-
brement nul. Il est appliqué sur la structure portante soudée 
électroniquement.

Cutout dimensions in cm

Dimensions du trou pour l'encastrement exprimées en cm

1,8

1,8

39,4

43

11,5

15

51

47,4

1,8

1,8

3,5

F 543/BE

    18,75            40             18,75

   6                48

                  

 

6

77,5

60

Summary of Contents for F 2010 Series

Page 1: ...IE F 2010 BUILT IN ELECTRIC BARBECUE WITH FLUSH EDGE DEPTH CM 51 BARBECUE LECTRIQUE ENCASTRABLE AVEC BORD SURBAISS PROF 51 CM Art F 543 BE GB Class 3 FR Class 3 INSTRUCTIONS MANUAL LIVRET D INSTRUCTIO...

Page 2: ...nchement au r seau lectrique 10 Donn es techniques lectriques 10 Mise au rebut 10 Sch ma lectrique F 543 BE 11 Etiquette technique 12 INDEX Important directions page 3 Technical and structural feature...

Page 3: ...est impor tant de respecter ces simples normes de s curit ne touchez pas l appareil avec les mains ou les pieds mouill s ou humides n utilisez pas l appareil avec les pieds nus ne permettez pas aux e...

Page 4: ...PIERRES DE LAVE FIRE PROOF FILTER FILTRE ANTI FEU DRIP TRAY LECHEFRITE ELECTRONICALLY WELDED SUPPORTING FRAME STRUCTURE PORTANTE SOUDEE ELECTRONIQUEMENT HEAT INSULATION PANEL PANNEAU THERMOISOLANT TH...

Page 5: ...ve la grille le su port universel et les brides porte plats pour utiliser la vaste gamme d accessoires fournis sur demande Le barbecue est un plan de cuisson multifonctions utiliser comme un feu g ant...

Page 6: ...r la cuisson avec les plaques et les casseroles il est indis pensable d enlever la grille poser le support universel adapter les pattes de support des casseroles la hauteur d sir e et en n poser les p...

Page 7: ...ande et l gumes bouillis p tes soupes pos n 4 fritures de poissons et ufs viande saut e d but de cuisson des r tis pos n 5 fritures pr parer rapidement pos n 6 aliments frits pommes de terre etc ELECT...

Page 8: ...particulier des parties lectriques d brancher la prise de courant ou plus simplement teindre l interrupteur g n ral Toutes les parties en acier inox se maintiendront dans l tat d origine part le brun...

Page 9: ...par du personnel quali D baller le barbecue en liminant avec soin les mat riaux divers servant de protection L appareil encastrer devra tre mont dans l l ment pr vu qui devra tre d coup aux dimensions...

Page 10: ...s Disposal of disused electrical appliances The Community WEEE Directive concerning the disposal of Electrical and Electronic Appliances sets out to protect the envi ronment by recycling and reducing...

Page 11: ...ort earthing MO Terminal board item PA 299 CA Power supply cord cross section 3x1 5 Legende PB Prise bipolaire 10A art 5113 MC Mise la terre panneau de commande RESP R gulateur d nergie pour r sistanc...

Page 12: ...inexactitudes contenues dans opuscule et imputables des erreurs d imprimerie ou de transcription pour les dommages aux choses ou aux personnes en cas de non observation de toutes les normes de pr vent...

Reviews: