18

AIR EXHAUST PIPE.

Assemble extremity 15 on the pipe.
Assemble the pipe on the air conditioner in the exhaust air outlet 10.

- Through a wall: 
Make a hole in the wall with diameter adapted to part
17.
Insert part 17 in the hole and extremity of the exhaust
pipe in this part.
If you do not use the air conditioner, you can close the
hole using the cover of part 17.

- Through the window or the door:
Assemble window accessory 14 on the exhaust pipe extremity.
Open door or window and put the extremity of the pipe through it. (Fig. 6
and 6bis)

If you have a sliding window, use kit 18 and insert the exhaust pipe
extremity in the opening.

Note : 
- Exhaust pipe can be as 1m50 long. The shorter it is, the more powerful your unit will be. Do not use

additional exhaust pipe. (Fig. 7)

- The pipe must not be damaged or bent. (Fig. 8)

Fig. 6

Fig.8

Fig. 7

Fig. 6 bis

7

MISE EN PLACE DE LA GAINE D’ÉVACUATION DE L’AIR CHAUD.

Monter l’extrémité 15 sur la gaine.
Positionner la gaine sur le climatiseur dans le logement arrière 10.

- A travers un mur : 
Réaliser dans le mur un trou de diamètre adapté à la
pièce 17.
Insérer la pièce 17 dans le trou, puis l’extrémité de la
gaine dans cette pièce.
Si vous enlevez votre climatiseur, montez le couvercle
de la pièce 17.

- Par la fenêtre ou la porte entre ouverte :
Monter l’accessoire pour fenêtre 14 sur l’extrémité de la gaine.
Ouvrir la porte ou la fenêtre et faire sortir cette extrémité en la coinçant
avec la porte ou la fenêtre. (Fig. 6 et 6bis)

Si vous avez une fenêtre coulissante, monter le kit 18 et insérer l’extrémité
de la gaine dans l’ouverture prévue à cet effet.

REMARQUE : 
- La gaine d’évacuation de l’air chaud peut s’étendre jusqu’à 1m50. Plus elle est courte, plus le
climatiseur sera performant. Ne pas rallonger la gaine. (Fig. 7)
- La gaine ne doit pas être endommagée ou pliée. (Fig. 8)

Fig. 6

Fig.8

Fig. 7

Fig. 6 bis

Summary of Contents for AC 10 FT

Page 1: ...du recyclage de la r utilisation mat rielle ou par les autres formes de r utilisation des appareils usag s Veuillez vous adresser votre municipalit pour conna tre la d chetterie comp tente Instructio...

Page 2: ...l ext rieur dans un environnement humide pr s d une baignoire d une douche ou d une piscine Ne pas immerger cet appareil ou le cordon d alimentation Cet appareil est livr avec un c ble d alimentation...

Page 3: ...mal Unit is damaged Make it repair by a qualified person When there is something wrong with your unit contact a qualified person 3 CARACT RISTIQUES Marque ALPATEC R f rence du mod le AC 10 FT Compress...

Page 4: ...it Do not use chemical solvent Use a dry and wet cloth to clean the outside of the unit Anti dust air filter If the anti dust air filter is dirty the air conditioner will be less performing Clean the...

Page 5: ...the unit is running Set remaining time before stopping using J Each pressure adds or removes half an hour from 0 5 to 12h Remaining time before stopping is displayed on VFD screen and adjusted every h...

Page 6: ...PEED Use touche VITESSE M Each pressure fan speed changes according to following diagram LOW MEDIUM HIGH DRY ONLY MODE During the dry operation the fan speed cannot be adjusted Low speed will be set a...

Page 7: ...g 8 Fig 6 Fig 8 Fig 7 Fig 6 bis 7 MISE EN PLACE DE LA GAINE D VACUATION DE L AIR CHAUD Monter l extr mit 15 sur la gaine Positionner la gaine sur le climatiseur dans le logement arri re 10 A travers u...

Page 8: ...pondance sur t l commande J 2 K 3 L 5 M 6 N 4 Sur l cran de la t l commande les pictogrammes des diff rents param tres s afficheront MISE EN MARCHE Brancher l appareil celui ci met un son bip Ouvrir l...

Page 9: ...a touche M A J pour arr ter l appareil Celui ci met un son bip et s arr te de fonctionner PROGRAMMATION Pour programmer un d part diff r de l appareil presser une fois la touche TEMPS M lorsque l appa...

Page 10: ...e bac est plein l erreur E2 s affiche sur l cran VFD l appareil s arr te de fonctionner Pour vider le bac arr ter le climatiseur positionner le bac eau amovible 16 sous le bouchon de vidange 7 retirer...

Page 11: ...ctrique est endommag e La faire changer Le fusible ou le cordon Rapporter votre appareil chez un d alimentation de l appareil sont r parateur agr qui proc dera la endommag s r paration L appareil s ar...

Page 12: ...plied and recommended by the manufacturer This could be dangerous and may damage the appliance Do not use if power cord or appliance is damaged Only use this appliance for domestic purpose following t...

Reviews: