Use M5 bolts or screws with a maximum head height of 4 mm, such as hexagon socket head (DIN
7984) cap screws with low head.
This method ensures excellent, but intrusive fixation of the Aloxy Pulse to an asset suitable for
instance for movement detection and vibration monitoring. Typical applications are manual valve
position monitoring by attachment to a flat valve lever or a flat spoke of the valve wheel, vibration
monitoring of the surface of rotating equipment, asset tracking of mobile vehicles, attachment to a
wooden surface, etc.
It is best to use the following bolts and nuts:
LOW-BULB HEAD of max SCREW WITH HEXAGON SOCKET ISO 7380-1 STAINLESS STEEL A2
M5X10
SELF-LOCKING HEXAGON NUT WITH PLASTIC WASHER DIN 985 STAINLESS STEEL (STAINLESS
STEEL) A2 M5
k (max.)
2.75 never more than 3,5mm!
D.
Installation on a flat metallic surface using
two
magnets
:
CAUTION
The magnet material has been specifically chosen to provide a long-term stable magnetic field.
However, as with any magnet, care must be taken when handling the magnet assembly.
NOTICE
Device damage.
Torque on screws regarding plastic mounting bracket. The maximum torque of the mounting plate
must not be exceeded 1 Nm (0.73 ft lb).