User’s manual of recovery vent
�
lators HRU-M
�
n
�
stA
�
r-W-450
Tech
n�
cal data
ww
w.
ve
nt
�l
at
�
on
-a
l
no
r.c
o.
uk
5
SEC
1
Average
-37
,
41
A
Warm
-12
,
67
E
Cold
-76
A
+
Typology
B�d�rect�onal
Type of dr�ve
Var�able speed
Heat recovery system
Recuperat�ve
Thermal eff�c�ency
%
90
,
5
Max�mum flow rate (@0Pa)
m³
/h
m³
/h
m³
/s
450
Max�mum flow rate (@100Pa)
370
Electr�cal power �nput at max�mum flow
W
169
Sound power level at reference flow rate
L
w
a
57
,
3
Reference flow rate
0
,
072
Reference pressure d�fference
Pa
50
SPI
2
W
/(
m³
/
h
)
0.259
Control factor and typology
1/Manual
Declared leakage rates
0.3-Internal
0.4-External
M�x�ng rate
%
0
Pos�t�on and descr�pt�on of f�lter warn�ng
www.ventilation-alnor.co.uk
Instruct�on of gr�lles
www.ventilation-alnor.co.uk
Model
HRU-MinistAir-W-450
Trade Mark
ALNOR
Internet address
www.ventilation-alnor.co.uk
A�r flow rate sens�v�ty
N/R
Indoor/outdoor a�r t�ghtness
N/R
AEC
3
Average
8.6
Warm
8.1
Cold
13.9
AHS
4
Average
46
Warm
20.8
Cold
89.9
¹ Specific Energy Consumption [kWh/(m².a)]
² Specific Power Input (W/(m³/h))
³ Annual Electricity Consumption [kWh electricity/a]
Annual Heating Saved [kWh primary energy/a]
*Technical data according to UE No. 1254/2014 (ErP).
4