Mounting the hood body

• Before hooking up the hood body, adjust the 2

screws Vr located on the hood body connection
points so that they are at the half way point.

• Hook the hood body to the mounted bracket.
• Adjust the screws Vr to level the hood body.

Should the installer consider it necessary, the hood
can be fixed to the wall using two more screws
with wall plugs, which can be positioned from
inside the hood canopy.

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left to the installer.

• To install a ø 120 mm air exhaust connection,

insert the reducer flange 9 on the hood body
outlet.

• Fix the pipe in position using sufficient pipe

clamps (not supplied).

• Remove any activated charcoal filters.

RECIRCULATION VERSION AIR OUTLET

• Push fit connection 15 onto the air outlet.
• Insert the connection extension pieces laterally

14.1 in connection 15.

• Make sure that the outlet of the extension pieces

14.1 is horizontally and vertically aligned with
the chimney outlets. If this is not the case, adjust
the position by either reversing the connection
extension pieces 14.1 or by pushing connector
15 all the way in.

• Ensure that the activated charcoal filters have been

inserted.

9

ø 120

ø 150

Vr

14.1

15

Summary of Contents for AEE 100 E

Page 1: ...Dunstesse AEE 100 E...

Page 2: ...ecommendations contained in this Instruction Manual your appliance will give you constant high performance and will remain efficient for many years to come RECOMMENDATIONS AND SUGGESTIONS 12 CHARACTER...

Page 3: ...aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of cl...

Page 4: ...13 GB 328 1000 360 1000 30 360 440 440 150 CHARACTERISTICS Dimensions...

Page 5: ...mney comprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 1 Hood Conn...

Page 6: ...the wall Mark the wall at the centres of the holes in the bracket Place bracket 7 2 1 on the wall as shown at X mm below the first bracket X height of the upper chimney section supplied and 324 mm fr...

Page 7: ...r rigid pipe 150 or 120 mm the choice of which is left to the installer To install a 120 mm air exhaust connection insert the reducer flange 9 on the hood body outlet Fix the pipe in position using su...

Page 8: ...e of the fan Flue assembly Upper exhaust flue Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brack...

Page 9: ...off at low speed Used to provide a contin uos and silent air change in the presence of light cooking vapours V2 Speed Medium speed suitable for most operating conditions given the optimum treated air...

Page 10: ...THE ACTIVATED CHARCOAL FILTER The filter is not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently for particularly heavy usage Remov...