PAGE
44
ALMAC s.r.l.
Identification
Function and
Status
Description of the function
1
Display
Display of the hours of operation and machine status,
with an indication of any alarms.
2
Emergency
Button
EMERGENCY STOP
3
Key selector
MACHINE ON / OFF
Left position (0) Machine turned off.
Right position (1) Machine turned on.
4
Key selector
RAPID COUPLINGS SELECTOR (OPTIONAL)
Left position
(OFF)
The rapid hydraulic connections (on
the right side of the machine) are
disabled and the machine works
normally.
Right position
(ON)
Pressure is applied to the rapid
hydraulic connections (on the right
side of the machine), all the machine
functions are disabled.
5
Connection plug
Plug for the connection of electricity to the network.
Required for handling the AC motor (110V or 220V) and
for recharging of the traction batteries.
6
3-pole outlet
12V auxiliary outlet (Connection for powering of winch kit
if present)
Attention: the 20A recharge is only necessary if a current is available from the
panel of max 10Aac, but, mainly,
use the 40A recharge to maintain the
optimal state of the batteries.
3.3
Battery charging indication (ELC
–
BI-ENERGY Version)
To recharge the batteries of the machine it is necessary to connect the
electrical outlet to the connection plug located on the ground control panel (See
photo)
Summary of Contents for MULTI-LOADER 6.0
Page 39: ...PAGE 39 ALMAC s r l...
Page 53: ...PAGE 53 ALMAC s r l...
Page 110: ...PAGE 110 ALMAC s r l 8 ATTACHMENTS 8 1 Declaration of conformity FAC SIMILE...
Page 112: ...PAGE 112 ALMAC s r l MANDATORY ROUTINE INSPECTIONS Date Observations Seal Signature...
Page 123: ...PAGE 123 ALMAC s r l 8 4 Hydraulic diagram See attachment 8 5 Wiring diagram See attachment...