TABLE OF CONTENTS
SECTION 1. GENERAL INFORMATION ..................................................................................... 2
SECTION 2. MEETING CODES .................................................................................................. 3
SECTION 3. DETERMINING CONDENSER LOCATION ........................................................... 3
SECTION 4. REFRIGERANT PIPING CONNECTIONS ............................................................. 4
SECTION 5. ELECTRICAL CONNECTION ................................................................................ 5
SECTION 6. REFRIGERANT CHARGE ..................................................................................... 6
SECTION 7. CHECKOUT PROCEDURE .................................................................................... 7
SECTION 8. MAINTENANCE ..................................................................................................... 7
SECTION 9. TROUBLE-SHOOTING CHART ............................................................................ 9
SECTION 1. GENERAL INFORMATION
These instructions cover the installation of the following
split system 13+ SEER condensing unit. The dimensions
are illustrated in Figure 1. Physical and electrical
specifications are provided in Table 2.
Read this manual and any instructions packaged with
separate equipment required to make up the system prior
to installation.
The outside unit is designed to be placed alongside or at the
back of the home, remote from the indoor coil. The outdoor
unit has been factory run-tested and all components of the
system are ready for easy, immediate installation.
A through inspection of the shipping container should be
made immediately upon receiving your unit. Look for any
punctures or openings, and if it appears that damage has
occurred, it should be noted on the freight bill before signing.
The delivering carrier should be contacted immediately to
inspect damage, and no installation work should begin until
this inspection is completed. The manufacturer assumes
no responsibility for installation of incorrectly shipped units.
To alert you to potential hazards, we use the signal words
“WARNING” and “CAUTION” throughout this manual.
“WARNING” alerts you to situations that could cause or
result in serious injury or death. “CAUTION” alerts you to
situations that could cause or result in minor or moderate
injury or property damage. For a safe and reliable
installation be sure to read and follow all warnings and
cautions.
We also use the words “must” and “should” in this manual.
“Must” is mandatory. “Should” is advisory.
WARNING:
These instructions
are intended as an aid to licensed service
personnel. Improper installation may
damage equipment, void the warranty,
and can create a hazard, resulting in
injury or death.
WARNING:
The manufacturer is not
responsible for the performance of a mismatched
system. The outdoor unit must be installed with
a compatible indoor unit as designated in the
specification data or in the Directory of Certified
Unitary Air Conditioners published by the Air
Conditioning and Refrigeration Institute. Using
unmatched components may not only affect the
performance of the system but may also void the
warranty of the equipment.
SERIES NOMENCLATURE
REFRIGERANT
4 - R410a
UNIT TYPE
AC - Air Conditioner
HP - Heat Pump
SERIES
13 - 13 SEER Condensing Unit
14 - 14 SEER Condensing Unit
NOMINAL COOLING CAPACITY
018 - 18,000 BTUH
042 - 42,000 BTUH
024 - 24,000 BTUH
048 - 42,000 BTUH
030 - 30,000 BTUH
060 - 60,000 BTUH
036 - 36,000 BTUH
VOLTAGE
A - 208/230-1-60
B - 208/230-3-60
COMPRESSOR
S - Scroll Compressor
CONDENSER COIL
A - AI/AI Coil
C - Cu/AI Coil
PRODUCT GENERATION
# - Revision Number
4 AC 13 042 A S A *