TABLE OF CONTENTS

SECTION 1.  GENERAL INFORMATION   .....................................................................................   2

SECTION 2.  MEETING CODES   ..................................................................................................   3

SECTION 3.  DETERMINING CONDENSER LOCATION   ...........................................................    3

SECTION 4.  REFRIGERANT PIPING CONNECTIONS   .............................................................    4

SECTION 5.  ELECTRICAL CONNECTION   ................................................................................    5

SECTION 6.  REFRIGERANT CHARGE   .....................................................................................    6

SECTION 7.  CHECKOUT PROCEDURE  ....................................................................................    7

SECTION 8.  MAINTENANCE   .....................................................................................................    7

SECTION 9.  TROUBLE-SHOOTING CHART   ............................................................................    9

SECTION 1.  GENERAL INFORMATION

These instructions cover the installation of the following 

split system 13+ SEER condensing unit.  The dimensions 

are illustrated in Figure 1.  Physical and electrical 

specifications are provided in Table 2.

Read this manual and any instructions packaged with 

separate equipment required to make up the system prior 

to installation.

The outside unit is designed to be placed alongside or at the 

back of the home, remote from the indoor coil.  The outdoor 

unit has been factory run-tested and all components of the 

system are ready for easy, immediate installation.

A through inspection of the shipping container should be 

made immediately upon receiving your unit.  Look for any 

punctures or openings, and if it appears that damage has 

occurred, it should be noted on the freight bill before signing.  

The delivering carrier should be contacted immediately to 

inspect damage, and no installation work should begin until 

this inspection is completed.  The manufacturer assumes 

no responsibility for installation of incorrectly shipped units.

To alert you to potential hazards, we use the signal words 

“WARNING” and “CAUTION” throughout this manual. 

 

“WARNING” alerts you to situations that could cause or 

result in serious injury or death.  “CAUTION” alerts you to 

situations that could cause or result in minor or moderate 

injury or property damage.  For a safe and reliable 

installation be sure to read and follow all warnings and 

cautions.

We also use the words “must” and “should” in this manual.  

“Must” is mandatory.  “Should” is advisory.

 WARNING:

 These instructions 

are intended as an aid to licensed service 

personnel.  Improper installation may 

damage equipment, void the warranty, 

and can create a hazard, resulting in 

injury or death.

 WARNING:

  The manufacturer is not 

responsible for the performance of a mismatched 

system.  The outdoor unit must be installed with 

a compatible indoor unit as designated in the 

specification  data  or  in  the  Directory  of  Certified 

Unitary Air Conditioners published by the Air 

Conditioning and Refrigeration Institute.  Using 

unmatched components may not only affect the 

performance of the system but may also void the 

warranty of the equipment.

SERIES NOMENCLATURE

REFRIGERANT

4 - R410a

UNIT TYPE

AC - Air Conditioner

HP - Heat Pump

SERIES

13 - 13 SEER Condensing Unit

14 - 14 SEER Condensing Unit

NOMINAL COOLING CAPACITY

018 - 18,000 BTUH 

042 - 42,000 BTUH

024 - 24,000 BTUH 

048 - 42,000 BTUH

030 - 30,000 BTUH 

060 - 60,000 BTUH

036 - 36,000 BTUH

VOLTAGE

A - 208/230-1-60

B - 208/230-3-60

COMPRESSOR

S - Scroll Compressor

CONDENSER COIL

A - AI/AI Coil

C - Cu/AI Coil

PRODUCT GENERATION

# - Revision Number

4   AC   13   042   A   S   A   *

Page 2

Installer’s Information Manual

Summary of Contents for 4AC13018ASA1

Page 1: ...documents listed above You should become familiar with these instructions as it will be helpful in avoiding any needless service costs or operational problems Keep these instructions as long as you k...

Page 2: ...ou to potential hazards we use the signal words WARNING and CAUTION throughout this manual WARNING alerts you to situations that could cause or result in serious injury or death CAUTION alerts you to...

Page 3: ...n Agency EPA has issued various regulations regarding the introduction and disposal of refrigerants in this unit Failure to follow these regulations may harm the environment and can lead to the imposi...

Page 4: ...d be give to water drainage away from the outdoor unit Drain holes in the base pan must be kept clear SECTION 4 REFRIGERANT PIPING CONNECTIONS Undersizedlinesetswillincreasetherefrigerantpressure drop...

Page 5: ...ighten This opens the valve completely The gauge port is open accessible at all times CAUTION Extreme care should be used when brazing joints Keep torch away from condenser cabinet aluminum coil and p...

Page 6: ...hich have Thermostatic Expansion Valve TXV as the expansion device For proper sub cooling readings a standard high side gauge is required for pressure readings 1 Measure the outdoor air temperature T1...

Page 7: ...ing unit for unusual noise and undue vibration 5 Allow the system to operate until it is balanced or stabilized approximately 30 minutes before making further checks 6 Remove manifold gauge hoses and...

Page 8: ...t Installer s Information Manual Page 8 SUB COOLING CHART FOR UNITS WITH THERMOSTATIC EXPANSION VALVES 18 16 14 12 10 8 6 4 60 65 70 75 80 85 90 95 100 105 110 115 Remove Refrigerant Add Refrigerant S...

Page 9: ...ect voltage Defective overload protector Refrigerant undercharge At compressor terminals voltage must be 10 of nameplate marking when unit is operating Replace check for correct voltage Add refrigeran...