Allstar LEADER PLUS LPX1000 Series Installation And Owner'S Manual Download Page 3

The LPX1000 Vehicular Gate Operator will provide convenience and 
assurance to the ultimate users for many years.  It is ruggedly built of 
the finest materials and has been thoroughly inspected and tested at the 
factory.  It has many features that will aid in the installation and testing 
of the complete gate system.  The LPX1000 is certified to comply with 
the ANSI / UL Standard for Safety 325. 
 

 

The LPX1000 slide gate operator (models without suffix or with suffix 
“S” only) is designated a Class I Residential Vehicular Slide Gate 
Operator and is intended to operate a vehicular slide gate installed on a 
residential home, maximum of four single families in the dwelling, or a 
garage or parking area associated with such a home. The LPX1000 
vehicular gate operator (again models without suffix or with suffix “S” 
only) is also designated as a Class II Vehicular Slide Gate Operator for 
use in a commercial location or multi-family home. The LPX1000 
vehicular gate operator (all models) is also designated as a Class III 
(industrial location not intended to service the general public); and IV 
(secure or restricted access locations, i.e. airports and prisons).  

THE 

LPX1000 (with appropriate suffix) MAY BE USED IN ANY 
CLASS LOCATION. 

Because the LPX1000 (as well as gate operators sold by other 
manufacturers) is designed to start and move gates weighing as much as 
1300 pounds, or more, the LPX1000 is capable of producing high levels 
of force.  It is important in the design of the total gate system that 
designers, installers and users be aware of the hazards that may be 
associated with the 

IMPROPER

 design, installation and use of 

vehicular gate systems and gate operators. 
The gate operator is only one part of a complete automatic gate 
operating system.  As each location and usage is different, a properly 
designed system will include all applicable safety devices. 

As the designer and installer

 of the 

GATE SYSTEM

, you must 

advise the purchaser on the proper use of the gate system.  

The LPX1000 has exclusive CGA2K™ Technology that provides 
several features to help reduce the hazards of your gate system. 

 

Built-In Overload Detector Sensing System 

The LPX1000 has a built-in "overload detector" that can help reduce 
the hazards of your gate system.  This device, however, must not be 
considered as the primary defense system.  Consider all available 
options (electric leading edges, photoelectric sensors, protective screen 
mesh, etc) to eliminate hazards in your gate system design. 

 

The  LPX1000’s built-in overload detector will activate if there is an 
abrupt increase in motor current above that normally required to move 
the gate.  The overload detection point is an adjustable setting that must 
be determined at the time of installation.  This setting must be tested 
periodically to ensure proper operation. Diligent maintenance of the 
gate hinges and hardware will assure the most responsive operation of 
the overload detector.  See pages 14 and 16. 
 
ADVISE THE PURCHASER TO CHECK THE SENSITIVITY OF 
THE OVERLOAD PERIODICALLY AND, AFTER REMOVING 
THE CONTROL BOX COVER, LOG THE DATE TESTED ON THE 
LOG LOCATED ON PAGE 2 OF THIS MANUAL (See Figure 1, pg. 
2.) 
 

Connections for External Entrapment Prevention Sensors

 

Because all gate system installations are different, the LPX1000 control 
panel provides independent connections for Open and Close non-
contact (photoelectric) and contact (edge) sensors.  In this way a 
photoelectric sensor could be utilized to guard the gate area when 
closing and an edge sensor would provide the protection when opening.  
Depending on the particular application a combination contact and non-
contact sensor protection system for the open and close directions may 
provide more effective entrapment protection than a single device for 
both directions.  See pages 4, 5, 18, 21, and 22. 
 

 

Audio Alarm and Safe Secure™ Open/Close Push Button Enable-
on-Alarm Only (Patent Pending)  

The LPX1000 has an audio alarm that sounds when a second 
occurrence of the built-in overload activation is registered before an end 
limit (open or close) is reached.  The alarm continues to sound warning 
until a fixed wire input is activated or five (5) minutes pass.  As with 
the built-in overload detector,  Diligent maintenance of the gate rollers 
and track will avoid nuisance operation of the overload detector and 
thereby avoid nuisance operation of the audio alarm. The Safe Secure™ 
Open/Close Push Button Enable-on-Alarm Only feature can be set to 
provide a secure control station that will be functional in an emergency  
situation.  See pages 14, 16, and 22. 

SMART™  Self adjusting MAximum Run Timer (Patent Pending) 

 

The LPX1000 has a 

S

elf adjusting 

MA

ximum 

R

un 

T

imer, SMART™ 

(patent pending).  The amount of time for the first few cycles of 
operation are registered and averaged within the motor controller 
circuitry.  After the first few initial cycles, if the gate is activated and no 
other command is given or an end limit (open or close) is not reached in 
the previously counted cycle time plus approximately 2 seconds, the 
operator will be turned off.  See page 17. 

 

OTHER FEATURES

 

Optional Fail Secure Lock Mechanism:  

Models with -S suffix are 

equipped with a Fail Secure operator locking mechanism. The lock is 
active whenever the gate is not moving and must be released via the 
integral Solenoid Lock Lever to manually move the gate.  See Page 21, 
Manual Operation.

 

Auto Close Timer:

  Adjustable from 2 to 60 seconds, provides an 

automatic closure of the gate from the full open position.  See page 14. 

 

Timer Re-close On/Off Switch:  

Enables an automatic closure of the 

gate from a partially closed position if the close movement was initiated 
by the Auto Close Timer and the close cycle was interrupted by a non-
contact (photoelectric) sensor input.  See page 14. 

 

Diagnostic LEDs on the Motor Controller Board:

  Provides a visual 

indication of the status of the gate system operation.  See page 15. 

 

Built-In Free Exit and Reversing Loop Detector Sockets:  

Two loop 

detector sockets are built-in and pre-wired to the operator's control 
system.  Easily accessible terminals allow connection of the actual loop  
wires to the operator.  See pages 7, 10, and 20. 

NOTICE 

The important safeguards and instructions in this 
manual cannot cover all possible conditions and 

situations which may occur during its use,  It must be 
understood that common sense and caution must be 
exercised by the person(s) installing, maintaining, and 
operating the equipment described herein. Do not use 
this equipment for other than its intended purpose - 
operating a vehicular slide gate. 

 

NOTICE 

Before attempting installation, read this 
manual carefully so you will be thoroughly 

familiar with the features of the LPX1000 and its 
proper installation procedures. 

 

PRE INSTALLATION NOTES 

Summary of Contents for LEADER PLUS LPX1000 Series

Page 1: ...ehicular gate operators READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS Serial Date Installed Your Dealer PROVEN CGA2K TECHNOLOGY INSTALLATION AND OWNER S MANUAL LEADER P...

Page 2: ...ou and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instructions to avoid the hazard CAUTION Indicates a ME...

Page 3: ...00 control panel provides independent connections for Open and Close non contact photoelectric and contact edge sensors In this way a photoelectric sensor could be utilized to guard the gate area when...

Page 4: ...CAN BE MINIMIZED BY INSTALLING A MESH SCREEN ON THE GATE It is strongly recommended that the entire gate and adjacent fence area the gate covers when open be meshed or guarded such that a handhold or...

Page 5: ...RED POWER LIGHT IS NOT LIGHTED HIGH VOLTAGE AC IS STILL PRESENT NEVER LEAVE THE INSTALLATION WITH THE HANDY BOX OR OUTER COVERS REMOVED ALWAYS TURN OFF THE POWER BEFORE ATTEMPTING SERVICE OF EITHER T...

Page 6: ...ng adjustment to prevent one operator from overloading the other The electrical hookup is made in the junction box located in the left front corner of the frame see Figure 7 Page 7 For conduit placeme...

Page 7: ...o one detector See Figure 8 above Two different types of installations will usually be encountered 1 If the driveway material is already in place saw cuts will be needed to accommodate the loop wires...

Page 8: ...INSULATED WIRE WIRE SIZE SHOULD BE 16zGA STRANDED OR LARGER C INSTALLING THE OPERATOR TOOLS REQUIRED The following tools and materials are required for proper installation of the operator 1 Two 3 4 wr...

Page 9: ...purpose Run flexible conduit from the point where the conduit exits the pad and attach it to the bottom of the right junction box at the front of the frame Review Figure 5 Page 6 If the hook up exits...

Page 10: ...e operator side wall The actual loop is installed in the concrete or asphalt surface in accordance with the manufacturer s instructions and the information outlined earlier in this manual see Page 7 C...

Page 11: ...now complete Connect one of the two wires for the relay to terminal 4 RADIO OPEN or terminal 3 ALTERNATE depending on the function desired see descriptions on the chart on page 17 and 18 and the othe...

Page 12: ...nd facing outwards if the operator is on the right side of the gate it s a right hand installation If the operator is on the left side of the gate it s a left hand installation The operator is shipped...

Page 13: ...lug it into the connector labeled LEFT HAND Locate the 3 position limit switch wire harness connector midway down on the right side of the controller board Switch it to the position labeled LEFT HAND...

Page 14: ...nuous signal required to move the gate when in the alarm mode SWITCH 1 ON Gate does not respond to pushbutton input when in the normal mode Continuous signal required to move the gate when in the alar...

Page 15: ...he Motor Close light stays ON 7 Connect to Terminal 11 Reversing Loop Observe that both Motor lights are ON momentarily and then the Motor Close light goes OUT and the Motor Open light stays ON 8 Conn...

Page 16: ...re the power to the operator Restart the gate and give the leading edge a firm blow with the heal of your palm Don t stand directly in the gate s path while testing the Overload Force The obstruction...

Page 17: ...nal for most HOLD OPEN functions Direct input to control system independent of the Loop Sockets Once activated the gate will open fully Activation while the gate is closing will cause it to re open Co...

Page 18: ...ld be connected here and to terminals 16 COMMON Multiple devices may be connected in parallel NAME DESCRIPTION 12 OPEN EDGE Momentary or continuous signal This input is active only when referenced to...

Page 19: ...IO OPEN ALTERNATE 16 15 13 14 12 9 10 7 8 5 6 3 4 2 1 24 VAC 24 VAC YEL YEL YEL YEL SOLENOID OPEN LIMIT RH CLOSED LIMIT RH WHT YEL RED LIMIT WIRE CONNECTIONS WHT COM COMMON RED YEL NO TRANSFORMER YEL...

Page 20: ...and observe that the REVERSING LOOP light comes ON the operator control board and the gate reopens 2 FREE EXIT VEHICLE DETECTOR Pre test Test the vehicle detector independently using the presence lamp...

Page 21: ...e or other need to move the gate manually without disconnecting the operator chain Take off the operator cover by first removing any lock attached to the lock tab on the operator front then lift the c...

Page 22: ...ers for exposed rollers Each safety feature is a separate component in your gate system Read and follow all instructions for each of the components of your unique system Ensure that all instructions f...

Page 23: ...hanical problems on the gate and gate hardware before installing the gate operator Have a qualified service technician make repairs to the gate and gate hardware AVOID ENTRAPMENT Stay away from the pa...

Page 24: ...from the date of purchase for multi family and commercial use To obtain service contact your dealer To obtain service under this warranty the buyer must obtain authorization instructions for the retu...

Reviews: