7  CLOSE 

Momentary or continuous signal. On/
Off mode set by Switch #1

 

WITH SWITCH 1 OFF:

 Once activated the gate will close fully.  

Activation while the gate is opening has no effect. Continuous 
signal required to move the gate when in the alarm mode.  

WITH SWITCH 1 ON:

 Gate does not respond to pushbutton 

input when in the normal mode. Continuous signal required to 
move the gate when in the alarm mode.  

 

8  STOP 

Momentary or continuous signal.   

Overrides all other signals.  Once activated, the gate will 
immediately stop and await a new command.  If the STOP 
input is continuously activated, the gate will not move. 

 

9  OPEN PHOTO 

Momentary or continuous signal.  

This input is active only when referenced to the opening 
direction, it has no effect on the gate when closing or about to 
close.  If activated when the gate is opening the gate will stop, 
pause and reverse in the close direction for 1/2 second 
(approx. 2 inches) and stop.  Continuous activation will 
prevent the gate from moving in the open direction.  When the 
input is removed normal operation is resumed.  This input is 
intended for photoelectric eye systems and other non-contact 
devices as appropriate.  Connect here and to terminal #16 
COMMON.  Multiple devices may be connected in parallel.  

10  CLOSE PHOTO  Momentary or continuous signal.  

This input is active only when referenced to the closing 
direction, it has no effect on the gate when opening or about to 
open.  If activated when the gate is closing the gate will stop, 
pause and reverse in the open direction for 1/2 second 
(approx. 2 inches) and stop.  Continuous activation will 
prevent the gate from moving in the close direction.  When the 
input is removed normal operation is resumed.  If the Timer-
To-Close function initiated the close movement and Switch S2 
(Re-close)  is ON, the gate will automatically re-close from a 
partially closed position after the input to Close Photo is 
removed. Continuous activation while the gate is open will 
prevent the Timer-To-Close function (if enabled) from 
automatically closing the gate.   This input is intended for 
photoelectric eye systems and other non-contact devices as 
appropriate.  Connect here and to terminal #16 COMMON.  
Multiple devices may be connected in parallel.  

11  REVERSE 

Momentary or continuous signal.  

This input is active only when the gate is closing or when it’s 
fully open and the Close Timer is operative.  All stand-alone 
vehicle detectors, photo-eyes and active edges should be 
connected here and to terminals #16 COMMON.  Multiple 
devices may be connected in parallel.  

#  NAME 

DESCRIPTION 

12  OPEN EDGE 

Momentary or continuous signal.   

This input is active only when referenced to the opening direction, 
it has no effect on the gate when closing or about to close.  If 
activated when the gate is opening the gate will stop, pause and 
reverse in the close direction for 1/2 second (approx. 2 inches) and 
stop. Continuous activation will prevent the gate from moving in the 
open direction.  If a second activation occurs before the limit switch 
is activated the gate will stop and a require a renewed, intended 
input to move in the open direction and before an automatic 
activation device (timer, etc.) will operate. This input is intended for 
Electric Gate Edge systems and other minimum-contact devices as 
appropriate.  Connect here and to terminal #16 COMMON.  
Multiple devices may be connected in parallel.  

13  CLOSE EDGE 

Momentary or continuous signal.  

This input is active only when referenced to the closing direction, it 
has no effect on the gate when opening or about to open.  If 
activated when the gate is closing the gate will stop, pause and 
reverse in the open direction for 1/2 second (approx. 2 inches) and 
stop.  Continuous activation will prevent the gate from moving in 
the close direction. Continuous activation while the gate is open 
will prevent the Timer-To-Close function (if enabled) from 
automatically closing the gate.  If a second activation occurs before 
the limit switch is activated the gate will stop and a require a 
renewed, intended input to move in the close direction and before 
an automatic activation device (timer, etc.) will operate. This input 
is intended for Electric Gate Edge systems and other minimum-
contact devices as appropriate.  Connect here and to terminal #16 
COMMON.  Multiple devices may be connected in parallel. 

 

14  MASTER OPEN  Momentary or continuous signal.  Master 

(output configuration). 

This terminal is used to coordinate two independent systems (two 
control box/mechanical unit combinations controlling separate gate 
leaves).  Connects to terminal #6 (OPEN) in the companion control 
box and controls the direction of movement in the companion box 
(Switch S3 ON).  

 

 

15  MASTER CLOSE  Momentary or continuous signal.  Master 

(output configuration). 

This terminal is used to coordinate two independent systems 
controlling separate gate leaves.  Connects to terminal #7 
(CLOSE) in the companion control box and controls the direction of 
movement in the companion box (Switch S3 ON).  
 

 

16  COMMON 

Common connection for low voltage 
signal inputs, terminals 3 through 15. 

 TERMINAL STRIP REFERENCE CHART 

 D

: STARTING THE OPERATOR  

18 

Summary of Contents for LEADER PLUS LPX1000 Series

Page 1: ...ehicular gate operators READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS Serial Date Installed Your Dealer PROVEN CGA2K TECHNOLOGY INSTALLATION AND OWNER S MANUAL LEADER P...

Page 2: ...ou and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instructions to avoid the hazard CAUTION Indicates a ME...

Page 3: ...00 control panel provides independent connections for Open and Close non contact photoelectric and contact edge sensors In this way a photoelectric sensor could be utilized to guard the gate area when...

Page 4: ...CAN BE MINIMIZED BY INSTALLING A MESH SCREEN ON THE GATE It is strongly recommended that the entire gate and adjacent fence area the gate covers when open be meshed or guarded such that a handhold or...

Page 5: ...RED POWER LIGHT IS NOT LIGHTED HIGH VOLTAGE AC IS STILL PRESENT NEVER LEAVE THE INSTALLATION WITH THE HANDY BOX OR OUTER COVERS REMOVED ALWAYS TURN OFF THE POWER BEFORE ATTEMPTING SERVICE OF EITHER T...

Page 6: ...ng adjustment to prevent one operator from overloading the other The electrical hookup is made in the junction box located in the left front corner of the frame see Figure 7 Page 7 For conduit placeme...

Page 7: ...o one detector See Figure 8 above Two different types of installations will usually be encountered 1 If the driveway material is already in place saw cuts will be needed to accommodate the loop wires...

Page 8: ...INSULATED WIRE WIRE SIZE SHOULD BE 16zGA STRANDED OR LARGER C INSTALLING THE OPERATOR TOOLS REQUIRED The following tools and materials are required for proper installation of the operator 1 Two 3 4 wr...

Page 9: ...purpose Run flexible conduit from the point where the conduit exits the pad and attach it to the bottom of the right junction box at the front of the frame Review Figure 5 Page 6 If the hook up exits...

Page 10: ...e operator side wall The actual loop is installed in the concrete or asphalt surface in accordance with the manufacturer s instructions and the information outlined earlier in this manual see Page 7 C...

Page 11: ...now complete Connect one of the two wires for the relay to terminal 4 RADIO OPEN or terminal 3 ALTERNATE depending on the function desired see descriptions on the chart on page 17 and 18 and the othe...

Page 12: ...nd facing outwards if the operator is on the right side of the gate it s a right hand installation If the operator is on the left side of the gate it s a left hand installation The operator is shipped...

Page 13: ...lug it into the connector labeled LEFT HAND Locate the 3 position limit switch wire harness connector midway down on the right side of the controller board Switch it to the position labeled LEFT HAND...

Page 14: ...nuous signal required to move the gate when in the alarm mode SWITCH 1 ON Gate does not respond to pushbutton input when in the normal mode Continuous signal required to move the gate when in the alar...

Page 15: ...he Motor Close light stays ON 7 Connect to Terminal 11 Reversing Loop Observe that both Motor lights are ON momentarily and then the Motor Close light goes OUT and the Motor Open light stays ON 8 Conn...

Page 16: ...re the power to the operator Restart the gate and give the leading edge a firm blow with the heal of your palm Don t stand directly in the gate s path while testing the Overload Force The obstruction...

Page 17: ...nal for most HOLD OPEN functions Direct input to control system independent of the Loop Sockets Once activated the gate will open fully Activation while the gate is closing will cause it to re open Co...

Page 18: ...ld be connected here and to terminals 16 COMMON Multiple devices may be connected in parallel NAME DESCRIPTION 12 OPEN EDGE Momentary or continuous signal This input is active only when referenced to...

Page 19: ...IO OPEN ALTERNATE 16 15 13 14 12 9 10 7 8 5 6 3 4 2 1 24 VAC 24 VAC YEL YEL YEL YEL SOLENOID OPEN LIMIT RH CLOSED LIMIT RH WHT YEL RED LIMIT WIRE CONNECTIONS WHT COM COMMON RED YEL NO TRANSFORMER YEL...

Page 20: ...and observe that the REVERSING LOOP light comes ON the operator control board and the gate reopens 2 FREE EXIT VEHICLE DETECTOR Pre test Test the vehicle detector independently using the presence lamp...

Page 21: ...e or other need to move the gate manually without disconnecting the operator chain Take off the operator cover by first removing any lock attached to the lock tab on the operator front then lift the c...

Page 22: ...ers for exposed rollers Each safety feature is a separate component in your gate system Read and follow all instructions for each of the components of your unique system Ensure that all instructions f...

Page 23: ...hanical problems on the gate and gate hardware before installing the gate operator Have a qualified service technician make repairs to the gate and gate hardware AVOID ENTRAPMENT Stay away from the pa...

Page 24: ...from the date of purchase for multi family and commercial use To obtain service contact your dealer To obtain service under this warranty the buyer must obtain authorization instructions for the retu...

Reviews: