6. Technical Data

Dimensions: 

width = 64mm; length = 44.5mm;  height = 20mm

Battery type:  

Lithium SL-360/P – 3.6V – 2.3Ah, Part-No. 10128

Battery lifetime: 

approx. 10 years (at 20°C environmental temperature)

Protection class: 

IP 64 

Environment temperature: 

-15-55°C (Inside installation)

Characteristic of pulse emitter:
Min. pulse / pause duration:  

100ms/100ms 

Max. pulse frequency: 

5Hz

Ron : 

200

Ω

 (resistance during pulse)

Roff :

1M

Ω

 (resistance during intervall)

Max. bounce time:

15ms

Max. cable length:

30m

���������

��

��

��

��

��

��

��

��

��

� �

��

5

6

MA-Nr

. P 1069 / Art.-Nr

. 12202

technical standard: 11 2010

Allmess GmbH · Am Voßberg 11 · D - 23758 Oldenburg i.H.  
Telefon (0 43 61) 625-0 · Telefax (0 43 61) 625-250  
E-Mail: [email protected] · www.allmess.de
Zertifiziertes Unternehmen nach DIN EN ISO 9001: 2000 
Reg.-Nr. 000468 QM

mit staatlich anerkannten Prüfstellen:

für Messgeräte für Wasser 

für Messgeräte für Wärme

4.3 Programming of pulse value and reset of the index.

Press push-button (picture 3) for more than 2s and keep it pressed. A display loop will start(each display appr. 2s). An action (pro-
gramming) will occur, if the push button is released during the actual display. 

4.4 Finishing the installation (picture 4) 

Close the box cover and fix the front cover with screws to back cover. Stick the 
needed label version on the box cover. (Take attention to the chosen unit!)

• 

Protect the screws by user seals. 

• 

Use the inscription field to indicate the meter point (e.g. name of tenant, flat number 
etc.)

5. Reset and battery exchange

Value-Setting: the index of theTC-E can be adjusted to any value (see 4.3)

Battery exchange (see 4.1): after removing the battery the TC-E will switch to following states:
• 

TC-E without power <30s: Index and pulse value will be kept, TC-E will start counting with old settings. 

• 

TC-E without power >30s but <600s: Index and pulse value will be kept, TC-E will start with a display test (see 4.2) and starts 
counting with old settings. 

• 

TC-E without power >600s: Index and pulse value will be reset to default values, the pulse value has to be programmed. 

picture 4

Display

Display description /

Pulse value

Pulse value

programming action

version for volume

version for energy

Battery exchange
(only available in case of battery

disconnection)

Comma position: 0 digits

1m

3

(= 1000 L)

1 MWh (= 1000 kWh)

Comma position: 1 digit

0.1 m

3

(= 100 L)

0.1 MWh (= 100 kWh)

Comma position: 2 digits

0.01 m

3

(= 10 L)

0.01 MWh (= 10 kWh)

Comma position: 3 digits

0.001 m

3

(= 1 L)

0.001 MWh (= 1 KWh)

Programming the meter offset. Flashing digits can be modified by keeping the push button pressed. The selected 
value will be memorised by releasing the push bottom. Repeat pressing the push button to return to the program-
ming modus and select the next value on second position or leave the programming modus, as shown in example:

Restore last index before reset. (Only available 5 min after reset!)

hold

release

hold

release

12202_P1069  TC-E 2 engl-dt TS1110:P1069/12202  TC-E 2 engl/dt.  02.11.10  10:33  Seite 4

Summary of Contents for ITRON Telecontrol TC-E

Page 1: ...n die Anschlussklemmen einführen ggf Polarität beachten z B bei Open collector Anschlussklemmen festschrauben Kabel gemäß Abbildung verlegen Batterie wieder einstecken Polarität beachten Batterie wieder einstecken Polarität beachten Ein Display Selbstest der TC E wird gestartet Während des Displaytest werden 3 verschiedene Segmentmuster für je ca 3 Sekunden angezeigt 1 Allgemeines Die Fernanzeige ...

Page 2: ...sichern Gegebenenfalls mit Folienstift das Typenschild beschriften Mietername Wohnungsnummer etc Reset und Batteriewechsel Voreinstellung Die TC E kann bei Zählerwechsel auf einen beliebigen Wert voreingestellt werden siehe 4 3 Batteriewechsel siehe 4 1 ff Nach dem Abziehen der alten Batterie treten folgende Zustände auf Batteriewechsel innerhalb 30 s Zählerstand und Impulswertigkeit bleiben erhal...

Page 3: ...CB terminals Respect the polarity e g in case of open collector Fix the terminal screws Place cable inside theTC E Replace the battery Respect the polarity A display test starts During the test 3 different pictures are displayed each picture displayed for 3s 1 Generics TC E is a remote display for indexes of meters equipped with repetition output e g reed switch or open collector The pulse weight ...

Page 4: ...field to indicate the meter point e g name of tenant flat number etc 5 Reset and battery exchange Value Setting the index of theTC E can be adjusted to any value see 4 3 Battery exchange see 4 1 after removing the battery the TC E will switch to following states TC E without power 30s Index and pulse value will be kept TC E will start counting with old settings TC E without power 30s but 600s Inde...

Reviews: