7 / 16
6-1624982 - rev.1 - 20/05/2021
ENG
TABLE 3 - HYPER 600 technical characteristics
TECHNICAL CHARACTERISTICS
U.M.
HYPER 600
Recommended control board
BIOS2 24
BIOS2 120 /
ECO
BIOS2 230 /
ECO
Supply voltage and frequency
24 Vdc
120Vac 60Hz
230Vac 50Hz
Motor absorption
A
3
1
1
Motor power
W
70
120
230
Capacitor
μF
--
31,5
8
Motor speed
rpm
1700
1750
1450
Average opening time (90°)
sec.
25
25
30
Maximum gate size (Weight/Length)
100 kg / 4,5 m
140 kg / 3,5 m
200 kg / 2 m
150 kg / 4,5 m
190 kg / 3,5 m
250 kg / 2 m
200 kg / 4,5 m
240 kg / 3,5 m
300 kg / 2 m
Maximum thrust
N
1600
2000
2000
Service
%
70
50
50
Recommended daily cycles
n°
100
100
100
Weight of the motor
kg
7
8
8
Operating temperature
°C
-20°C ... +55°C
Degree of protection
IP
44
Emergency release
lever release with key
Internal mechanical stoppers
optional
TABLE 4 - Stem stroke
AVAILABLE STEM STROKE
U.M.
HYPER 400
HYPER 600
Without mechanical stoppers
mm
415
615
With 1 mechanical stopper (opening)
mm
395
595
With 2 mechanical stoppers (opening and closing)
mm
375
575
ATTENTION! ONLY FOR 24V MOTORS
IN NO CASE SHALL THE MAXIMUM WEIGHTS AND DIMENSIONS GIVEN IN THESE TABLES BE
EXCEEDED.
ALWAYS USE THE SLOWDOWNS SET BY THE CONTROL UNIT FOR THE MOVEMENT OF THE
GATE.
WARNING!
In the graph next to it is reported, as an explanatory example, the
relationship between weight and length of the door for the gearmo-
tor HYPER 400 230vac.
1,5
2,5
3
MT
kg
300
200
100
2
HYPER 400 230Vac