background image

7 / 16 

6-1624982 - rev.1 - 20/05/2021

ENG

TABLE 3 - HYPER 600 technical characteristics

TECHNICAL CHARACTERISTICS

U.M.

HYPER 600

Recommended control board

BIOS2 24

BIOS2 120 / 

ECO

BIOS2 230 / 

ECO

Supply voltage and frequency

24 Vdc

120Vac 60Hz

230Vac 50Hz

Motor absorption

A

3

1

1

Motor power

W

70

120

230

Capacitor

μF

--

31,5

8

Motor speed

rpm

1700

1750

1450

Average opening time (90°)

sec.

25

25

30

Maximum gate size (Weight/Length)

100 kg / 4,5 m
140 kg / 3,5 m
200 kg / 2 m

150 kg / 4,5 m
190 kg / 3,5 m
250 kg / 2 m

200 kg / 4,5 m
240 kg / 3,5 m
300 kg / 2 m

Maximum thrust

N

1600

2000

2000

Service

%

70

50

50

Recommended daily cycles

100

100

100

Weight of the motor

kg

7

8

8

Operating temperature

°C

-20°C ... +55°C

Degree of protection

IP

44

Emergency release

lever release with key

Internal mechanical stoppers

optional

TABLE 4 - Stem stroke

AVAILABLE STEM STROKE

U.M.

HYPER 400

HYPER 600

Without mechanical stoppers

mm

415

615

With 1 mechanical stopper (opening)

mm

395

595

With 2 mechanical stoppers (opening and closing)

mm

375

575

ATTENTION! ONLY FOR 24V MOTORS

IN NO CASE SHALL THE MAXIMUM WEIGHTS AND DIMENSIONS GIVEN IN THESE TABLES BE 
EXCEEDED.
ALWAYS USE THE SLOWDOWNS SET BY THE CONTROL UNIT FOR THE MOVEMENT OF THE 
GATE.

WARNING!

In the graph next to it is reported, as an explanatory example, the 
relationship between weight and length of the door for the gearmo-
tor HYPER 400 230vac.

1,5

2,5

3

MT

kg

300

200

100

2

HYPER 400 230Vac

Summary of Contents for HYPER 400

Page 1: ...HYPER Ambidextrous irreversible operator for swing door gates 6 1624982 ENGLISH rev 1 20 05 2021...

Page 2: ...WARNINGS 3 2 DESCRIPTION 3 3 LIST OF PACKAGING ACCESSORIES AND OVERALL DIMENSIONS 4 4 PRODUCT VIEW AND TECHNICAL CHARACTERISTICS 6 5 PRELIMINARY CHECKS 8 6 INSTALLATION 11 7 DECLARATION OF CONFORMITY...

Page 3: ...is provided with thermal protection that in case of prolonged use momentarily interrupts the movement The HYPER motor provides great flexibility of installation as you can install it with the motor b...

Page 4: ...ppers 0 1 2 0 1 2 230Vac 50Hz 12008100 12008101 12008102 12008130 12008131 12008132 120Vac 60Hz 12008110 12008111 12008112 12008140 12008141 12008142 24Vdc 12008120 12008121 12008122 12008150 12008151...

Page 5: ...790 HYPER 400 990 HYPER 600 810 HYPER 400 1010 HYPER 600 WITHOUT INTERNAL MECHANICAL STOPPERS WITH INTERNAL MECHANICAL STOPPERS 1 or 2 77 31 15 46 10 5 10 5 10 5 90 5 120 5 25 50 11 11 10 10 40 REAR...

Page 6: ...ate size Weight Length 100 kg 3 m 133 kg 2 5 m 200 kg 1 5 m 150 kg 3 m 183 kg 2 5 m 250 kg 1 5 m 200 kg 3 m 233 kg 2 5 m 300 kg 1 5 m Maximum thrust N 1600 2000 2000 Service 70 50 50 Recommended daily...

Page 7: ...s n 100 100 100 Weight of the motor kg 7 8 8 Operating temperature C 20 C 55 C Degree of protection IP 44 Emergency release lever release with key Internal mechanical stoppers optional TABLE 4 Stem st...

Page 8: ...ause they are not sufficiently safe WARNING The doors shall be firmly attached to the hinges of the columns shall not flex during movement and shall move without friction Before installing the motor i...

Page 9: ...tion of the various devices in a typical plant are listed in the table below and must be suitable for the type of installation for example we recommend a cable type H07RN F for outdoor installation TA...

Page 10: ...wards or upwards depending on your needs WHAT NOT TO DO Do not install on sloping gates Do not unduly bend the motor cable Do not install the bracket in the gate in weak points that may break 5 4 MOTO...

Page 11: ...73 104 968 102 160 987 108 992 110 983 105 978 102 973 100 968 98 180 991 100 986 98 981 96 976 94 971 93 966 91 200 989 92 984 90 982 90 981 90 976 88 964 85 TABLE 8 HYPER 600 Recommended installatio...

Page 12: ...g dimensions For the anchor of the piston it is necessary to use additional supports not supplied together with the fixing brackets supplied These supports shall be appropriate to the dimension of the...

Page 13: ...with the bracket already installed to the gate and temporarily fix the bracket to the gate 6 Verify that the motor is on level 7 Carry out some manual opening and closing movements in order to verify...

Page 14: ...gnet and therefore the mechanical stopper as far as possible from the gate hinge 5 Repeat the operations described above also for the mechanical stopper of closing bringing the gate first in the posit...

Page 15: ...ectrical connections and in case of wear of the cables replace them 4 Unlock the motor and move the gate manually by checking that the movement is fluid In case it is necessary to put a layer of lubri...

Page 16: ...ction for disposal according to the methods provided by the regulations in force in your territory or return the product to the seller when buying a new equivalent product WARNING the regulations in f...