13
en
English
17
X
Y
20.
Cut off and discard the female spade terminal from
the wire that was connected to the Zettler relay. Strip
off the appropriate amount of wire insulation and install
wire (
X
, Figure 17) into a 3 pin lever lock (
Y
, Figure 17,
Ref. 10) from the kit contents.
18
Z
AA
21. From the kit contents, locate and select the black 16
AWG wire (
Z
, Figure 18, Ref. 2). Cut the black 16
AWG wire in half, and strip the ends of the cut wires.
On each of the cut wires crimp a blue fork terminal
(
AA
, Figure 18, Ref. 8) on one of the ends.
22. Install the fork terminal end of each black wire (
BB
,
Figure 19a-b) on DC post 1 of 725 light relay 1 and 2.
Then, install the bare wire ends of the two black wires
into the open ports of the 3 port lever lock (
CC
, Figure
19a-b) that was installed in Step 20.
19a
BB
725 Relay 2
BB
725 Relay 1
CC
725 Relay
Connection Detail
19b
BB
725 Relay 2
725 Relay 1
CC
23. On Zettler light relay 2 disconnect the remaining 16
AWG wire (
DD
, Figure 20) from the DC power spade.
This wire should be leading from the divider panel of
the component block. On Zettler relay 1 disconnect
the 16 AWG wire from the same spade.
Not for