508034-02
Issue 2135
Page 4 of 49
95G1UH100CE20X Performance (Less Filter)
External
Static
Pressure
in. w.g.
Air Volume / Watts at Different Blower Speeds
Bottom Return Air, Side Return Air with Optional Return Air
Base, Return Air from Both Sides or Return Air from Bottom and
One Side.
Single Side Return Air −
Air volumes in
bold
require field fabricated
transition to accommodate 20 x 25 x 1 in. air filter in order to maintain
proper air velocity.
High
Med-High
Medium
Med-Low
Low
High
Med-High
Medium
Med-Low
Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.00
2156 722 1922 497 1723 370 1589 215 1420 211
2102 118 1833 489
1688 170 1590 300 1375 209
0.10
2112 738 1851 511 1681 388 1552 326 1380 227
2064 730 1809 504
1658 384 1540 314 1347 224
0.20
2076 748 1808 533 1636 403 1525 334 1340 244
2038 749
1789 514 1623 402 1507 331 1325 242
0.30
2035 768 1782 542 1604 425 1488 349 1290 259
2011 760
1761 531 1594 413 1472 348 1266 246
0.40
2009 772 1749 558 1572 433 1441 362 1248 266
1968 770
1726 549 1561 431 1435 355 1247 264
0.50
1942 776 1715 580 1533 452 1424 374 1213 281
1920 776
1685 560 1527 443 1394 374 1199 278
0.60
1881 746 1681 584 1512 468 1357 382 1157 293
1849 741
1660 578 1489 455 1356 379 1154 286
0.70
1790 715 1634 599 1459 474 1319 401 1136 306 1777 723 1622 593 1439 473 1317 395 1124 301
0.80
1702 679 1582 613 1432 491 1300 418 1084 312 1682 681 1588 602 1407 488 1288 408 1067 308