Allied 2HP13 Installation/Start-Up Instructions/Homeowners Information Manual Download Page 1

506162-02

Issue  0847

      Page  1  of   14

These instructions m ust be read and understood com pletely before attem pting installation.

Safety  Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     2

Unit  Location  &  Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     2

Rooftop Installation & Recommendations . . . . . . . . . . . . . . . . . . . .   3

Indoor  Coil  Piston  Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     3

Refrigeration  Line  Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     3

Installation  of  Line  Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     4

Leak  Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     4

Evacuating  &  Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     4

Opening  Service  Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     5

Electrical  Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     5

Control  Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     5

Start-Up  Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     6

Adjusting  charge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     6

Defrost  System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     7

Single  Phase  Wiring  Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     9

3  Phase  Wiring  Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Homeowner's  Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Installation or repairs made by unqualified persons can result in hazards to you and others.  Installation
MUST conform with local building codes and with the National Electrical Code NFPA 70/ANSI C1-1993 or
current edition and Canadian Electrical Code Part 1 CSA C22.1.

2HP13/14 & 4HP13 SPLIT SYSTEM HEAT PUMP

INSTALLATION / START-UP INSTRUCTIONS

/HOMEOWNERS INFORMATION MANUAL

TABLE OF CONTENTS

These units are designed for use in residential and light commercial type buildings.  Heat Pumps may only be
installed with indoor combinations listed in the Air-Conditioning and Refrigeration Institute (ARI) Directory of
Certified Products. 

Inspect the unit for any damage before installation.  If damage is found, notify the transportation company
immediately and file a concealed damage claim.

Im proper installation, adjustm ent, alteration, service or m aintenance will void the warranty.  The qualified installer or
agency m ust use factory-authorized kits or accessories when added to this products.  Refer to the individual instructions
included with the specific accessory kit.

NOTE

These instructions are intended as a general guide and do not supersede national, state or local codes in any way.

These instructions must be left with the property owner.

Summary of Contents for 2HP13

Page 1: ...l Code Part 1 CSA C22 1 2HP13 14 4HP13 SPLIT SYSTEM HEAT PUMP INSTALLATION START UP INSTRUCTIONS HOMEOWNERS INFORMATION MANUAL TABLE OF CONTENTS These units are designed for use in residential and light commercial type buildings Heat Pumps may only be installed with indoor combinations listed in the Air Conditioning and Refrigeration Institute ARI Directory of Certified Products Inspect the unit f...

Page 2: ...nnected to factory approved indoor unit outdoor unit contains system refrigerant charge for operation with indoor unit of the same size when connected by 15 ft of field supplied tubing For proper unit operation check refrigerant charge using charging information located on control box cover IMPORTANT Maximum liquid line size is 3 8 in O D for all residential applications including long lines Outdo...

Page 3: ...rant line lengths DO NOT LOCATE THE UNIT On brick concrete blocks or unstable surfaces Near clothes dryer exhaust vents Near sleeping area or near windows Under eaves where water snow or ice can fall directly on the unit with clearance less than 2 ft from a second unit with clearance less than 4 ft on top of unit Operating Ambient The minimum outdoor operating ambient in cooling mode is 55 F and t...

Page 4: ...th water using a wet rag Leave rag on fitting body and re wet with water to help cool area Leak Check Refrigeration lines and indoor coil must be checked for leaks after brazing and before evacuation The recommended procedure is to apply a trace amount of vapor refrigerant approximately two ounces or 3 psig into the line set and indoor coil then pressurize with 150 psig of dry nitrogen Use a refri...

Page 5: ... at the line side of the contactor in the control box of the outdoor unit Follow the appropriate wiring diagram attached to inside of the access panel Proper circuit protection recommendations are indicated on Unit Rating Plate Time delay fuses are required to prevent blowing due to starting current the current in rush when equipment starts is referred to as the Locked Rotor Amps or LRA A fuse of ...

Page 6: ...or line sets shorter than 15 feet in length remove charge For line sets longer than 15 feet add charge Oil charge is sufficient for all line lengths Before final adjustment is made to the refrigerant charge it is imperative that proper indoor airflow be established Airflow will be higher across a dry coil versus a wet coil Blower charts are calculated with a dry or wet coil basis Recommended airfl...

Page 7: ...ously Filter Drier The outdoor unit is equipped with a bi flow filter drier If replacement is necessary order new dryer according to the service parts manual Emergency Heat Function Room Thermostat An emergency heat function is designed into some room thermostats This feature is applicable when isolation of outdoor unit is required or when auxiliary electric heat is staged by outdoor thermostats W...

Page 8: ... seconds going in and out of the defrost mode when the compressor delay jumper is removed NOTE The 30 second off cycle is not functional when jumpering the TEST pins Time Delay The timed off delay is 5 minutes long The delay help to protect the compressor from short cycling in case the power to the unit is interrupted or a pressure switch opens The delay is bypassed by placing the timer select jum...

Page 9: ...506162 02 Issue 0847 Page 9 of 14 H P SINGLE PHASE WIRING DIAGRAM ...

Page 10: ...506162 02 Issue 0847 Page 10 of 14 H P 3 PHASE WIRING DIAGRAM ...

Page 11: ... manufacturers The information below is typical for most thermostats Ask your dealer for specific information regarding the model of thermostat installed Temperature Setting Levers Most heat pump thermostats have 2 temperature selector levers one for heating and one for cooling Set the levers or dials to the desired temperature set points for both heating and cooling Avoid frequent temperature adj...

Page 12: ...s dryers and fall off from trees can be drawn into coils by movement of the air Clogged condenser coils will lower the efficiency of your unit and could cause damage to the condenser Periodically debris should be brushed from the condenser coils Use a soft bristle brush with light pressure only DO NOT damage or bend condenser coil fins Damaged or bent fins may affect unit operation Painted Surface...

Page 13: ...lete model and serial number b proof of required periodic maintenance installation date and location c an accurate description of the problem W ARRANTY LIMITATIONS 1 This warranty is void if the covered equipment is removed from the original installation site 2 This warranty does not cover damage or defect resulting from a flood wind fire lightning mold or installation and operation in a corrosive...

Page 14: ...506162 02 Issue 0847 Page 14 of 14 NOTES ...