GS1380 Technical Manual
Page 6
Specifications
Sensor Type
Sony ICX285AL CCD (ICX285AQ for color)
Sensor Shutter Type
Progressive Interline
Image Resolution
1360 x 1024 pixels
Pixel Size
6.45μm x 6.45μm
Optical Format
2/3 inch
Lens Mount
C-mount with adjustable back focus
Color Sensor Filter Pattern
†
Bayer
Full Resolution Frame Rate
30 fps
Frame Rate (640 x 480 ROI)
55 fps
I/O
1 isolated input/output, 1 non-isolated input/output,
1 RS-232 input/output
Power Requirements
Less than 3.5W
††
(5V to 16V)
†††
A/D
14 bit
Output
12 bit
Trigger latency*
2us for non-isolated I/O, 10us for isolated I/O
Trigger Jitter*
±20ns for non-isolated I/O, ±0.5us for isolated I/O
Tpd*
10ns for non-isolated I/O, 1.3us for isolated I/O
Operating Temperature
0 to 50 Celsius***
Operating Humidity
20 to 80% non-condensing
Weight
187g
Hardware Interface Standard
IEEE 802.3 1000BASE-T, 100BASE-TX
Software Interface Standard
GigE Vision Standard 1.0
Regulatory
CE, FCC, RoHS
†
Applies to GS1380C only.
††
Power consumption will increase with reduced ROI imaging and color interpolation.
†††
Nominal operating voltage is 12V. Cameras have been tested at 12V.
*
See Notes on Triggering in the Addendum.
***DUE TO THE SMALL PACKAGING AND HIGH SPEED OF THE GS CAMERAS, SPECIAL CARE IS REQUIRED TO
MAINTAIN A REASONABLE OPERATING TEMPERATURE. IF THE CAMERA IS TO BE OPERATED IN A WARM
ENVIRONMENT, IT IS SUGGESTED THAT THE CAMERA BE MOUNTED ON A HEAT SINK SUCH AS A METAL BRACKET