Prosilica GB Technical Manual V2.0.3
34
Camera interfaces
Out 1 – opto-isolated
Out 1 is optically isolated and should be used in noisy environments. Out 1
requires a pull up resistor of greater than 1 KΩ to the user’s 5 V logic supply. Tie
Camera GND
to
Isolated IO GND
to complete the external circuit. See
Camera I/
O opto-isolated user circuit example
for more information.
Out 2– non-isolated
Out 2
signal is not electrically isolated and can be used when environmental
electrical noise is inconsequential and faster trigger response is required. Use
Signal GND
to complete the external circuit. The output signal is a
low voltage
TTL, maximum 3.3 V
.
Not suitable for driving loads in excess of 24 mA
. See
Camera I/O non-isolated user circuit example
for more wiring information.
Signal ground
Signal Ground
must be connected to the user’s external circuit ground if
In 2
or
Out 2
is to be used, or if the RS-232 port is to be used. Note that
Signal Ground
is common with
Camera GND
; however, it is good practice to provide a separate
ground connection for power and signal.
Video iris
This signal can be used to drive the video input of a video iris lens. See
Video iris
user circuit example
section for wiring information.
Reserved
These signals are reserved for future use and should be left disconnected.