
GX1660 User Manual
70-0057A-A
Allied Vision Technologies (Canada) Inc.
28
Triggering during the Readout State
o
For applications requiring the fastest triggering cycle time whereby the camera image sensor
is exposing and reading out simultaneously, then the User Trigger signal should be applied as
soon as a valid Trigger Ready is detected.
o
In this case, Trigger Latency and Trigger Jitter can be up to 1 line time since Exposure must
always begin on an Interline boundary.