 These signals only function as outputs and can be configured as follows: 

 

Exposing 

Corresponds to when camera is 
integrating light. 

Trigger Ready 

Indicates when the camera will accept a 
trigger signal. 

Trigger Input 

A relay of the trigger input signal used 
to “daisy chain” the trigger signal for 
multiple cameras. 

Readout 

Valid when camera is reading out data. 

Strobe 

Programmable pulse based on one of the 
above events. 

Imaging 

Valid when camera is exposing or 

reading out. 

GPO 

User programmable binary output. 

 

Any of the above signals can be set for active high or active low. 

RS-232 RXD and RS-232 TXD 

These signals are RS-232 compatible. These signals allow communication from the host system 
via  the  Ethernet  port  to  a  peripheral  device  connected  to  the  camera.  These  signals  are  not 
optically isolated and reference power ground.  If these signals are used in the system, care must 
be taken to prevent ground loop problems. 

USER GROUND 

This connection provides the user ground reference and return path for the isolated sync in and 
sync out signals.  This connection is necessary if any of the isolated sync signals are to be used.  
It is also recommended that this ground connection be physically close to the used sync signals 
to  prevent  parasitic  coupling.    For  example,  a  good  cable  design  would  connect  the  required 
signal on one conductor of a twisted pair and the isolated ground on the second conductor of the 
same twisted pair. 

USER VCC 

This  connection  provides  the  power  supply  for  the  isolated  sync  out  signals.    The  voltage 
requirement is from 5V to 24V DC. The current requirement for this supply is a function of the 
optical isolator collector current and the number of sync outs used in the system.  See the 

SYNC 

OUTPUT

  section  for  more  detail.  To  prevent  parasitic  coupling  this  connection  should  be 

physically close to the used SYNC OUT signals and USER GROUND. 

Summary of Contents for GX1660C

Page 1: ...Allied Vision Technologies Canada Inc www alliedvisiontec com tel 604 875 8855 fax 604 875 8856 2010 Allied Vision Technologies Inc All rights reserved USER MANUAL January 11 2010 GX1660 GX1660C...

Page 2: ...upported Features 3 Mechanical 4 Connections 5 Cleaning the Sensor 11 Adjusting the C mount 12 Network Card Configuration 13 GigE Sample Viewer and Filter Driver 17 Trouble Shooting 18 Addendum 21 GX...

Page 3: ...P SHIPPING MATERIAL Poor packaging of this product can cause damage during shipping VERIFY ALL EXTERNAL CONNECTIONS Verify all external connections in terms of voltage levels power requirements voltag...

Page 4: ...ter 0 5 s Operating Temperature 0 to 40 Celsius with standard housing 0 to 50 Celsius with thermal housing Operating Humidity 20 to 80 non condensing Size and Weight See mechanical diagrams Hardware I...

Page 5: ...0 seconds in 1 microsecond increments Gain 0 to 34dB Region of Interest ROI independent x and y control with 1 pixel resolution Horizontal Binning 1 to 8 pixels Vertical Binning 1 to 8 rows Pixel Form...

Page 6: ...GX1660 User Manual 70 0057A A Allied Vision Technologies Canada Inc 4 Mechanical GX C MOUNT...

Page 7: ...GX1660 User Manual 70 0057A A Allied Vision Technologies Canada Inc 5 Connections GX CONNECTION DIAGRAM...

Page 8: ...SYNC IN 2 12 SYNC OUT 2 GENERAL PURPOSE IO PORT AS SEEN FROM BACK OF CAMERA The General Purpose I O port uses a Hirose HR10A 10R 12PB connector on the camera side The mating cable connector is Hirose...

Page 9: ...a For best performance the connection for EXTERNAL POWER should be physically close to the POWER GROUND connection SYNC INPUTS 1 and 2 The input signals allow the camera to be synchronized to some ext...

Page 10: ...ER VCC R VCC USER GND USER SYNC OUT USER TRIGGER CIRCUIT T4 CAMERA CIRCUIT T2 TLP281 4GB 1 2 16 15 T3 IF 5mA CAMERA LOGIC SIGNAL 3 3V CAMERA LOGIC SIGNAL SYNC OUT SIGNAL T1 Various USER VCC values and...

Page 11: ...ted and reference power ground If these signals are used in the system care must be taken to prevent ground loop problems USER GROUND This connection provides the user ground reference and return path...

Page 12: ...tage requirements of 6V up to 12V or lenses which operate with bipolar voltages from 6V up to 12V This voltage level can be controlled through software The default voltage will be set to 6V The curren...

Page 13: ...he IR filter carefully using a small flat head screw driver Clean both sides of the IR filter using the same techniques as explained below for the sensor window DO NOT TOUCH ANY OPTICS WITH FINGERS OI...

Page 14: ...the locking ring is loose unthread the ring a few turns from the camera face A wrench suitable for this procedure can be provided by AVT Canada Inc P N 11 0048A Image to Infinity Use a c mount compat...

Page 15: ...Ethernet ports into a single data channel 1 Install a dual port network card in the host computer To achieve full camera performance you should use a Gigabit Ethernet card that supports Jumbo frames o...

Page 16: ...Windows firewall The camera will not work if the firewall is active If you installed the Prosilica GigE filter driver this step is not required 8 Perform Steps 1 8 for the other Ethernet adapter port...

Page 17: ...your system Click Next to continue 12 Select the two Ethernet ports to which the GX camera will be connected These ports will form our LAG or TEAM Click Next to continue 13 Choose Static Link Aggregat...

Page 18: ...Canada Inc 16 15 Once completed the properties of the TEAM LAG that has just been created will appear A new Network Connections Icon corresponding to the LAG group is created You have now completed th...

Page 19: ...net cable s and power Verify that the Green LED is a solid green Run Sample Viewer It will take a few seconds for the camera to be recognized especially if your camera is in DHCP mode If the camera do...

Page 20: ...s Use Cat5e or better cabling known to work Configure your NIC as outlined in Gigabit Ethernet Setup For Windows It should have an IP address of 169 254 x x Subnet Mask 255 255 0 0 This is the AutoIP...

Page 21: ...be on the same subnet as your NIC Camera is not listed or flashing Camera Unavailable There may be multiple NICs on your system set to the same subnet The camera can not know which card to resolve to...

Page 22: ...re or hardware trigger event to capture frames Packets are incoming but all dropping Be sure you have JumboFrames enabled on your NIC Otherwise decrease your PacketSize setting to 1500 All packets com...

Page 23: ...GX1660 User Manual 70 0057A A Allied Vision Technologies Canada Inc 21 Addendum...

Page 24: ...OGIC SYNC IN 1 180R 1 10W IF 5mA TLP281 4GB 1 2 16 15 TLP281 4GB 3 4 14 13 5V TO 24V IF 5mA VDD 3 3 442R 442R 5V TO 24V IF 5mA 100K SYNC OUT 4 CAMERA LOGIC SYNC OUT 4 D S G MMBF4393LT1G 3 3V LOGIC SYN...

Page 25: ...NOTES 1 CAMERA POWER 5V TO 24V 2 CAMERA POWER DOES NOT NEED TO BE THE SAME AS USER VCC 3 CAMERA GND DOES NOT NEED TO CONNECT TO USER GND 4 USER VCC MUST HAVE CURRENT CAPACITY TO SUPPLY IC CURRENT FOR...

Page 26: ...OM COMMON ZOOM FOCUS ZOOM FOCUS COMMON HIROSE 3240 8P C 50 1 2 3 4 5 6 7 8 TV ZOOM LENS UNIPOLAR TYPE ZOOM IRIS IRIS TV ZOOM LENS BIPOLAR TYPE HIROSE 3240 8P C 50 1 2 3 4 5 6 7 8 IRIS COMMON COMMON CO...

Page 27: ...5 Video Iris Connection VIDEO SIGNAL LENS GROUND 12V POWER POWER GROUND VIDEO AUTO IRIS LENS 1 2 3 4 JEITA CONNECTOR 1 2 3 4 LENS POWER 1 2 3 4 5 6 7 8 9 10 11 12 HIROSE HR10A 10P 12S 1 2 3 4 5 6 7 8...

Page 28: ...n Technologies Canada Inc 26 Trigger Timing Diagram User Trigger Logic Trigger Exposure Readout Trigger Ready Imaging Tpd Trigger Latency Interline Time Expose Start Delay Trigger Jitter Idle Register...

Page 29: ...e and indicates when the next Exposure cycle can begin such that the Exposure will end after the current Readout o Interline Time is the time between sensor row readout cycles o Imaging is high when t...

Page 30: ...the fastest triggering cycle time whereby the camera image sensor is exposing and reading out simultaneously then the User Trigger signal should be applied as soon as a valid Trigger Ready is detecte...

Page 31: ...Disabled an external trigger does not control end of acquisition AcqRec An AcqStart hardware trigger signal or the AcquisitionStart command must be received before your AcqRec trigger See Acquisition...

Page 32: ...g falling edge trigger EdgeAny rising or falling edge LevelHigh active high signal LevelLow active low signal FrameStartTriggerMode Determines how an image frame is initiated within an acquisition Fre...

Page 33: ...before the AcqRec trigger event with AquisitionFrameCount minus RecorderPreEventCount images being returned after the trigger event Valid only when AcquisitionMode equals Recorder NOTE at least one i...

Page 34: ...ureAutoTarget in which the autoexposure algorithm will not respond Can be used to limit exposure setting changes to only larger variations in scene lighting ExposureAutoAlg The following algorithms ca...

Page 35: ...n variation from GainAutoTarget in which the auto gain algorithm will not respond Can be used to limit gain setting changes to only larger variations in scene lighting GainAutoMax In dB Sets the upper...

Page 36: ...um driving voltage for closing the lens iris Typically this will be 150 however it may vary dependent on the lens reference voltage IrisVideoLevelMin In 10 mV units Limits the minimum driving voltage...

Page 37: ...lly this parameter does not require adjustment HeartbeatTimeout In milliseconds The maximum amount of time the camera will wait for a heartbeat command before timing out NOTE this value may need to be...

Page 38: ...opped StatPacketsDropped you will likely need to decrease this parameter StreamHold For controlling when the camera sends data to the host computer Normally the camera sends data to the host computer...

Page 39: ...al number of bytes per image frame Dependant on ROI PixelFormat and Binning ImageMode Binning is the summing of charge of adjacent pixels on a sensor to give a lower resolution but more sensitive imag...

Page 40: ...trigger FrameTrigger Active when an image has been initiated to start This is a logic trigger internal to the camera which is initiated by an external trigger or software trigger event Exposing Active...

Page 41: ...filter driver is not installed or is not activated StatFilterVersion Version of the filter driver being used StatFrameRate The current actual frame rate of the camera as received by the driver StatFr...