Configuration of the camera
STINGRAY Technical Manual
V2.2.0
289
Advanced register: frame counter
The
frame counter
feature is controlled by the following advanced feature
register:
Having this feature enabled, the current
frame counter
value (images read
out of the sensor, equivalent to # FrameValid) will be inserted as a 32-bit
integer value into any captured image.
Setting the
Reset
flag to 1 resets the frame counter to 0: the
Reset
flag is
self-cleared.
Additionally there is a register for direct read out of the frame counter value.
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Cycle offset 12 bit
Cycle count ...
Bit
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
... Cycle count 13 bit
Second count 7 bit
Table 146: Cycle timer layout
Note
L
Different to Marlin SIS:
Register 610 is only to be used to reset the frame counter.
Register
Name
Field
Bit
Description
0xF1000610 FRMCNT_STAMP
Presence_Inq
[0]
Indicates presence of this feature
(read only)
Reset
[1]
Reset frame counter
---
[2..31]
Reserved
0xF1000614 FRMCNT
[0..31]
Frame counter
Table 147: Advanced register:
Frame counter
Note
L
The 4 bytes of the
frame counter
value will be inserted as
the
5th to 8th byte of a line
.