Camera interfaces
OSCAR Technical Manual
V2.4.0
46
IO_OUTP_CTRL 1-2
The outputs (Output mode, Polarity) are controlled via two advanced feature
registers.
The
Polarity
flag determines whether the output is active low (0) or active
high (1). The
output mode
can be viewed in the table below. The current
status of the output can be queried and set via the
PinState
flag.
It is possible to read back the status of an output pin regardless of the output
mode. This allows for example the host computer to determine if the camera
is busy by simply polling the BUSY output.
Register
Name
Field
Bit
Description
0xF1000320
IO_OUTP_CTRL1
Presence_Inq
[0]
Indicates presence of this
feature (read only)
---
[1..6]
Reserved
Polarity
[7]
0: active low
1: active high (inverting)
---
[8..10]
Reserved
Output mode
[11..15]
Mode
see
Table 18: Output rout-
ing
on page 47
---
[16..30]
Reserved
PinState
[31]
RD: Current state of pin
WR: New state of pin
0xF1000324
IO_OUTP_CTRL2
Same as
IO_OUTP_CTRL1
Table 17: Advanced register:
Output control