background image

Quick Install Guide

7

C613-04017-01 REV F

d) At the switch, connect the positive feed to the + (positive) terminal and 

the negative feed to the - (negative) terminal. Tighten the terminals to 
between 0.6 and 0.8 Nm (0.041 to 0.055 pound-force per foot)

e) Ensure there are no exposed conductor strands

f)

Secure the supply cable (to the rack framework or similar object) so the 
connections are isolated from any forces applied to the cable

g) Ensure the circuit breaker is in the Off position

h) Connect the supply-cable wires to the circuit breaker

i)

Energise the circuit breaker

Figure 2: DC Power inlet terminals on a Rapier 24.

The Fault LED should flash for approximately 10 seconds as the switch 
runs internal tests. If the LED continues to flash or remains lit, refer to the

 

Rapier Switch Hardware Reference

 for troubleshooting information.

9.

Check that the Power LED on the switch’s front panel lights green

If the LED fails to light, refer to the

 Rapier Switch Hardware Reference

 for 

troubleshooting information.

10. Connect the Redundant Power Supply (Optional)

AC models of Rapier Switches have a Redundant Power Supply (RPS) 
connector on their rear panel.

The Switch is designed to operate with the AT-RPS8000 RPS, which can be 
purchased separately. Contact your authorised Allied Telesyn distributer 
or reseller for more information.

11. Connect the data cables

Make sure each cable connection is secure. The switch will now perform 
basic Layer 2 switching functions.

Configuring the Switch

Some configuration is necessary if you wish to enable the switch’s advanced 
switching capabilities. The switch can be configured via the Command Line 
Interface (CLI) or Graphical User Interface (GUI).

Using the CLI to configure a switch

1.

Connect a terminal or PC to the Terminal Port (ASYN0)

Using the supplied RS-232 DB9 straight-through cable, connect your 
terminal or PC to the RS-232 Terminal Port on the switch’s front panel.

NSM 0

Hot Swap

In Use

Swap

38-75VDC      , 2A

FOR CENTRALIZED DC 
POWER CONNECTION, 

INSTALL ONLY IN A 

RESTRICTED AREA

DC Power inlet

DC    INPUT

Summary of Contents for Rapier 24i

Page 1: ...RAPIER SWITCH QUICK INSTALL GUIDE ...

Page 2: ...ent without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein even if Allied Telesyn has been advised of known or should have k...

Page 3: ...updates can be downloaded from www alliedtelesyn co nz support rapier Rapier Switch Safety and Statutory Information Quick Install Guide Hardware Reference Software Reference Network Service Module NSM Quick Install Guide NSM Hardware Reference Port Interface Card PIC Quick Install Guide PIC Hardware Reference General Customer Support Visit www alliedtelesyn co nz for the latest documentation FAQ ...

Page 4: ...ck or on a level surface such as a desktop or bench When installing the switch choose a site that Allows adequate airflow around the switch and its vents Is free of dust and moisture Will maintain an ambient temperature range of 0 to 40º C 32 to 104º F and a humidity range of 5 to 95 non condensing Has a reliable and earthed grounded power supply circuit preferably dedicated and filtered Does not ...

Page 5: ...oose a suitable site for the switch Either a flat surface or 19 inch rack 4 Unpack the switch Verify the package contents If any items are damaged or missing contact your sales representative 5 Install expansion options If you purchased optional Uplink Modules a Network Service Module NSM or Port Interface Cards PICs install them now by following their individual installation guides These guides c...

Page 6: ...e grounded Circuit protection Use a 10 Amp circuit breaker To connect the DC supply a Ensure the supply cable is not live b Strip the supply cable wires to expose 8mm 0 31 in of bare conductor c At the switch connect the ground wire to the ground terminal The terminals can be identified by the diagram on the switch s rear panel see Figure 2 Tighten the terminal to between 0 6 and 0 8 Nm 0 041 to 0...

Page 7: ...to light refer to the Rapier Switch Hardware Reference for troubleshooting information 10 Connect the Redundant Power Supply Optional AC models of Rapier Switches have a Redundant Power Supply RPS connector on their rear panel The Switch is designed to operate with the AT RPS8000 RPS which can be purchased separately Contact your authorised Allied Telesyn distributer or reseller for more informati...

Page 8: ...onfigure the switch using the command line interface Change the password as soon as possible Leaving the manager account with the default password is a serious security risk Make sure you remember the new password as there is no way to retrieve it if it is lost Use the following command to change the account password set password 4 Load command line interface help files To access CLI help enter se...

Page 9: ...connected directly or through a LAN The PC should be running Internet Explorer 5 x or Netscape 6 2 2 with JavaScript enabled Internet Explorer can be found on the Documentation and Tools CD ROM that is bundled with your switch If you access the Internet through a proxy server set your browser to bypass the proxy for the IP address you just assigned to the VLAN1 interface Point your web browser at ...

Page 10: ...e Fault Red The switch or management software is malfunctioning 1 flash A switch fan has failed The LEDs will not indicate an RPS fan failure 3 flashes If an RPS is connected the switch s PSU Power Supply Unit has failed 4 flashes If RPS monitoring is enabled the RPS PSU has failed 5 flashes If RPS monitoring is enabled an RPS is not connected or is not operational RPS1 Redundant Power Supply Gree...

Page 11: ...software The Rapier Switch User Guide which provides an introduction to the switch s Graphical User Interface and its Layer 2 switching features The Network Service Module Quick Install Guide which outlines the procedure for installing an NSM and the Network Service Module Hardware Reference which provides detailed information on NSMs The Port Interface Card Quick Install Guide which outlines the ...

Reviews: