Rapier Switch

C613-04017-01 REV F

Figure 1: Rapier front panel and rear panel with AC power inlet.

8.

Apply DC power to the switch (for DC models)

Read the 

Safety and Statutory Information

 booklet before connecting a DC 

power supply. A copy of this booklet is included with each switch. It is also 
included on the Documentation and Tools CD-ROM, or can be 
downloaded from www.alliedtelesyn.co.nz/support/rapier/.

Only trained and qualified personnel should connect a DC power supply. Due 
to exposed terminals, DC powered switches should only be installed in 
Restricted Access Areas.

DC supply cable specifications:

Number of wires (cores): 3

Minimum size: 2.1mm

2

 (14 AWG)

Minimum cable rating: 600V, 90 degrees Celsius

DC power supply specifications:

48 VDC (39-60 VDC is acceptable)

Either positive grounded or negative grounded

Circuit protection:

Use a 10 Amp circuit breaker

To connect the DC supply:

a) Ensure the supply cable is not live

b) Strip the supply cable wires to expose 8mm (0.31 in.) of bare conductor

c)

At the switch, connect the ground wire to the ground terminal (The 

terminals can be identified by the diagram on the switch’s rear panel, 
see Figure 2). Tighten the terminal to between 0.6 and 0.8 Nm (0.041 to 
0.055 pound-force per foot)

STATUS

RESET

FAULT

PWR

RPS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

10BASE-T / 100BASE-TX

1

X

3

X

5

X

7

X

2

X

4

X

6

X

8

X

9

X

11

X

13

X

15

X

10

X

12

X

14

X

16

X

17

X

19

X

21

X

23

X

18

X

20

X

22

X

24

X

25

26

RS-232

TERMINAL PORT

100M LINK /        ACTIVITY

10M LINK /        ACTIVITY

HALF DUP/        COL

FULL DUP

PORT ACTIVITY

L /A

L /A

D/C

D/C

L /A

D/C

ASYN0

Layer 3 Fast Ethernet Switch

NSM 0

Hot Swap

In Use

Swap

Front panel

Uplink Module Bays

10/100 BASE Ports

Port LEDs

System 

LEDs

RS-232 Terminal Port

Rear panel

100-240 VAC

Power Inlet

RPS Inlet for

AT-PWR8000

NSM BAY

NSM Hot Swap

Button and LEDs

Summary of Contents for Rapier 24i

Page 1: ...RAPIER SWITCH QUICK INSTALL GUIDE ...

Page 2: ...ent without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein even if Allied Telesyn has been advised of known or should have k...

Page 3: ...updates can be downloaded from www alliedtelesyn co nz support rapier Rapier Switch Safety and Statutory Information Quick Install Guide Hardware Reference Software Reference Network Service Module NSM Quick Install Guide NSM Hardware Reference Port Interface Card PIC Quick Install Guide PIC Hardware Reference General Customer Support Visit www alliedtelesyn co nz for the latest documentation FAQ ...

Page 4: ...ck or on a level surface such as a desktop or bench When installing the switch choose a site that Allows adequate airflow around the switch and its vents Is free of dust and moisture Will maintain an ambient temperature range of 0 to 40º C 32 to 104º F and a humidity range of 5 to 95 non condensing Has a reliable and earthed grounded power supply circuit preferably dedicated and filtered Does not ...

Page 5: ...oose a suitable site for the switch Either a flat surface or 19 inch rack 4 Unpack the switch Verify the package contents If any items are damaged or missing contact your sales representative 5 Install expansion options If you purchased optional Uplink Modules a Network Service Module NSM or Port Interface Cards PICs install them now by following their individual installation guides These guides c...

Page 6: ...e grounded Circuit protection Use a 10 Amp circuit breaker To connect the DC supply a Ensure the supply cable is not live b Strip the supply cable wires to expose 8mm 0 31 in of bare conductor c At the switch connect the ground wire to the ground terminal The terminals can be identified by the diagram on the switch s rear panel see Figure 2 Tighten the terminal to between 0 6 and 0 8 Nm 0 041 to 0...

Page 7: ...to light refer to the Rapier Switch Hardware Reference for troubleshooting information 10 Connect the Redundant Power Supply Optional AC models of Rapier Switches have a Redundant Power Supply RPS connector on their rear panel The Switch is designed to operate with the AT RPS8000 RPS which can be purchased separately Contact your authorised Allied Telesyn distributer or reseller for more informati...

Page 8: ...onfigure the switch using the command line interface Change the password as soon as possible Leaving the manager account with the default password is a serious security risk Make sure you remember the new password as there is no way to retrieve it if it is lost Use the following command to change the account password set password 4 Load command line interface help files To access CLI help enter se...

Page 9: ...connected directly or through a LAN The PC should be running Internet Explorer 5 x or Netscape 6 2 2 with JavaScript enabled Internet Explorer can be found on the Documentation and Tools CD ROM that is bundled with your switch If you access the Internet through a proxy server set your browser to bypass the proxy for the IP address you just assigned to the VLAN1 interface Point your web browser at ...

Page 10: ...e Fault Red The switch or management software is malfunctioning 1 flash A switch fan has failed The LEDs will not indicate an RPS fan failure 3 flashes If an RPS is connected the switch s PSU Power Supply Unit has failed 4 flashes If RPS monitoring is enabled the RPS PSU has failed 5 flashes If RPS monitoring is enabled an RPS is not connected or is not operational RPS1 Redundant Power Supply Gree...

Page 11: ...software The Rapier Switch User Guide which provides an introduction to the switch s Graphical User Interface and its Layer 2 switching features The Network Service Module Quick Install Guide which outlines the procedure for installing an NSM and the Network Service Module Hardware Reference which provides detailed information on NSMs The Port Interface Card Quick Install Guide which outlines the ...

Reviews: