59
Chapter 5
Troubleshooting
This chapter contains information on how to troubleshoot the media
converter if a problem occurs.
Note
For further assistance, please contact Allied Telesis Technical
Support at
Problem 1:
The PWR LED on the media converter is off.
Solutions:
The unit is not receiving power. Try the following:
Verify that the power cord is securely connected to the power
source and to the DC connector on the back panel of the media
converter.
Verify that the power outlet has power by connecting another
device to it.
Try using another power adapter of the same type that came with
your media converter.
Verify that the voltage from the power source is within the required
levels for your region.
Problem 2:
The SYS LED on the media converter is off.
Solution:
An internal component on the unit is damaged or not working
properly. Try power cycling the unit. If power cycling does not clear the
fault, return the unit to Allied Telesis.
Problem 3:
The SYS LED on the media converter is blinking slowly.
Solutions:
The media converter may be in Loopback mode or an error is
present on the unit. Try power cycling the unit.
A transmit fault may be occurring on the SFP+ module. The media
converter will try to clear this error, but if the error persists, try the
following:
Remove and re-seat the SFP+ module.
Try a different SFP+ module.
Verify the SFP+ module is the correct type for your application.
Summary of Contents for MMC10G Series
Page 8: ...List of Figures 8 ...
Page 10: ...List of Tables 10 ...
Page 14: ...14 ...
Page 34: ...Chapter 1 Overview 34 ...
Page 44: ...Chapter 2 Beginning the Installation 44 ...
Page 52: ...Chapter 3 Installation 52 ...
Page 58: ...Chapter 4 Powering On and Cabling the Media Converter 58 ...
Page 62: ...Chapter 5 Troubleshooting 62 ...