AT-CV5M02
| Converteon Series Management Card
Technical Specifications
Status Indicators
LED State Description
PWR
Green
The CPM card is receiving power
OFF
The CPM card is not receiving power
RDY
Green
The CPM card has passed diagnostics
and is ready
OFF
The CPM card has failed diagnostics
and is not ready
FLT
Red
The CPM card has experienced fault
condition
OFF
The CPM card has reported no fault
condition
LK
Green
Link established on the card Ethernet
port
OFF
No link established on the card
Ethernet port
AT
Flashing TX/RX activity established on the
card Ethernet port
OFF
No activity established on the card
Ethernet port
FD
Green The CPM card is operating in
full-duplex mode
OFF
The CPM card is operating in
half-duplex mode
Connectors
RS232
Female DB-9
Baud speed 1200 ~ 115200bps
Ethernet 10/100TX, auto MDI/MD-IX
Management Features
Management Interfaces
RS232 (Local Login): Username and Password
protected (Enable/Disable Local
Login)
Telnet (Remote Login): Username and Password
protected (Enable/Disable Remote
Login)
SNMP Managers:
Named SNMP Manager
(Enable/Disable SNMP)
(Up to 4 SNMP manager)
DHCP
DHCP client (Enable/Disable)
System Warnings
Over temperature warning
PSU failure warning
Fan failure warnings
Blade failure
Insert/Remove Power Supply
Insert/Remove fan module
Insert/Remove blade
Operational Warnings
Link Up/Down
Event Logging
Time and date stamp for all log entries
Internal log
Syslog
Administration
Diagnostics
Firmware upgrade (Mangement card)
Firmware upgrade (Blade firmware)
Configure MissingLink
TM
Configure Smart MissingLink
TM
Configure link monitor
Configure IEEE 802.3ah OAM
Web GUI interface
Management card redundancy
Multiple local and remote line card image download
Local and remote line card configuration backup in
management card
Auto-copy line card configuration
Local and remote line card port flow control
Support NTP client
Broadcast Storm Protection
Physical Specifications
Dimensions
2.2cm x 7.3cm x 13cm
(H x W x L)
(.855” x 2.89” x 5.10”)
Weight:
0.60 lbs
0.27 kg
Package Contents
One AT-CV5M02 CPM card
One DB-9 RS-232 serial cable
Installation guide
Warranty card
Power Characteristics
Input supply voltage
5vDC, 3.3vDC
Maximum input current 1.15 A (5vDC), 0.86 A (3.3vDC)
Power consumption
9.6 watts maximum
Environmental Specifications
Operating temperature 0°C to 40°C
(32°F to 104°F)
Storage temperature
-25°C to 70°C
(-13°F to 158°F)
Operating relative humidity 5% to 90% RH
(non-condensing)
Storage relative humidity 5% to 95% RH
(non-condensing)
Operating altitude range up to 3,048m (10,000ft)
Standards
EMI part 15:
FCC class A, EN55022 class A, VCCI class A, C-Tick, CE
Immunity:
EN55024
Safety:
UL60950-1 (cULUS), EN60950-1 (TUV)
Quality and Reliability:
MTBF> 100,000 hrs
Electrical Interfaces:
UL60950 (UL/cULus)
EN60950 (TUV)
CSA22.2 No. 950
Ordering Information
AT-CV5M02
SNMP management module
Associated Products
AT-CV1000-xx
Single slot Converteon chassis
AT-CV1203-xx
Two slot Converteon chassis
AT-CV5000-xx
18 slot, Converteon chassis