All installation methods shall be in accordance with national and local
regulations and practices. The wiring method should include the use of
Listed wire/cable acceptable for the application per the National Code,
and should be one that an Authority Having Jurisdiction (AHJ) can
approve per the Code.
No wiring to the product should be exposed in lengths beyond 140
feet, as circuits should avoid exposure to accidental contact with
lightning and power conductors in accordance with NEC Article 725-
57 (NEC 2002). The installer should also consider Articles 210, 240,
250, 770 and 810 of the National Electrical Code (NEC).
The pluggable external power supply provided with the unit should be
mounted indoors. If other power supplies are employed, they should
be LISTED ITE with a Limited Power Source (PLS) output, LISTED
with an NEC Class 2 output, or another NEC Class 2 source of power
compliant with Article 725.
Warning:
Fuse Rating (for Service Personnel).
For continued protection against risk of fire replace only with the same
type and rating of fuse. (Fuse F1: rating 125VAC, 3A.)