background image

AT-FS7016
AT-FS7024

Fast Ethernet Smart Switches

Installation Guide

PN 613-50469-00 Rev A

Summary of Contents for AT-FS7016

Page 1: ...AT FS7016 AT FS7024 Fast Ethernet Smart Switches Installation Guide PN 613 50469 00 Rev A...

Page 2: ...their respective owners Allied Telesyn Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided...

Page 3: ...portant L annexe B contient les instructions de s curit relatives l installation de cet quipement Lorsque vous voyez le symbole reportez vous l annexe B pour consulter la traduction de ces instruction...

Page 4: ...utstyret N r du ser pner du til Tillegg B for finne den oversatte sikkerhetsinformasjonen p nsket spr k Importante O Anexo B cont m advert ncias de seguran a traduzidas para instalar este equipamento...

Page 5: ...g Management Software Updates ix Tell Us What You Think ix Chapter 1 Overview 1 Key Features 3 Status LEDs 4 Port Speed 5 Duplex Mode 5 Auto MDI MDI X 6 RS 232 Terminal Port 6 Power Requirements 7 Net...

Page 6: ...i Chapter 3 Troubleshooting 21 Appendix A Technical Specifications 23 Physical 23 Environmental 23 Electrical Rating 24 Agency Compliance 24 Pinout Assignments 25 Appendix B Translated Safety and Emis...

Page 7: ...rtable Document Format PDF from the Allied Telesyn web site at www alliedtelesyn com You can view the documents online or download them onto a local workstation or server Once you have installed your...

Page 8: ...nical support online by accessing the Allied Telesyn Knowledge Base from the following web site kb alliedtelesyn com You can use the Knowledge Base to submit questions to our technical support staff a...

Page 9: ...ites Allied Telesyn web site http www alliedtelesyn com Allied Telesyn FTP server ftp ftp alliedtelesyn com If you would prefer to download new software from the Allied Telesyn FTP server from your wo...

Page 10: ......

Page 11: ...wisted pair port has a RJ 45 connector and a maximum operating distance of 100 meters 328 feet These ports are capable of Auto negotiating to 10 or 100 Mbps and feature half and full duplex operation...

Page 12: ...he back panel of the AT FS7016 and AT FS7024 switches Figure 3 Back Panel RS 232 Terminal Port Status LEDs AT FS7024 24 Port Fast Ethernet Smart Switch POWER LINK ACT 100M FDX 1 2 3 4 5 6 7 8 9 10 11...

Page 13: ...X twisted pair ports Auto MDI MDI X on all ports Full or half duplex operation on all ports RS 232 terminal port for out of band management Supports the following software functions Port mirroring Por...

Page 14: ...r is applied to the switch LINK ACT Green Blinking OFF A valid link has been established on the port The port is transmitting data A link has not been detected on the port 100M Green OFF The port is o...

Page 15: ...r send or receive data but not both at the same time However an end node operating in full duplex can send and receive data simultaneously The best network performance is achieved when an end node can...

Page 16: ...ion of the port on the device to which it is connected and then configures itself appropriately This features allows you to use either a straight through or crossover cable when connecting a device to...

Page 17: ...ents The AT FS7016 and AT FS7024 switches use a universal internal switching power supply Allied Telesyn ships power cords with these units to the U S Continental Europe and the U K The AT FS7016 swit...

Page 18: ...re 4 allows each end node to directly connect to a 10 100Base TX twisted pair port on an AT FS7016 switch This gives each end node a dedicated 10 Mbps or 100 Mbps link Figure 4 Power Workgroup Topolog...

Page 19: ...et frame from hub to hub only when the destination end node for the frame is on a different hub than the end node that originated the frame This reduces the amount of unnecessary data traffic in each...

Page 20: ...9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 RS 232 TERMINAL PORT AUTO MDI MDI X 5 4 3 2 1 6 7 8 AT FS7024 24 Port Fast Ethernet Smart Switch POWER LINK ACT 100M FDX 1 2 3 4 5 6 7 8 9 10 11 12 13 1...

Page 21: ...your package If any item is missing or damaged contact your Allied Telesyn sales representative for assistance One AT FS7016 or AT FS7024 Fast Ethernet Smart Switch Four protective feet AT FS7016 only...

Page 22: ...configures itself automatically as MDI or MDI X when connected to an end node Consequently you can use either a straight through or crossover twisted pair cable when connecting any network device to a...

Page 23: ...switch and through its vents on the side and back are not restricted Use a dedicated power circuit or power conditioner to supply reliable power to the switch If you plan to install the switch in an...

Page 24: ...nt disconnect the power cord 7 Caution Pluggable Equipment The socket outlet should be installed near the equipment and should be easily accessible 8 Warning Electrical Type Class 1 Equipment This equ...

Page 25: ...flat secure surface leaving ample space around the switch for ventilation 4 Apply power to the switch by plugging the AC power cord into an AC power outlet then plug the other end of the power cord in...

Page 26: ...ecting the trunk cables to the switch before you have configured the software will result in a data loop which can adversely affect network performance For instructions on how to configure a port trun...

Page 27: ...To install the switch in a rack perform the following procedure 1 If attached remove the four protective rubber feet from the bottom on the unit For the AT FS7016 switch remove the protective feet fr...

Page 28: ...tch to the rack using two screws not provided for each side as shown in Figure 11 Figure 11 Installing the Switch to the Rack 4 Apply power to the switch by plugging the AC power cord into an AC power...

Page 29: ...ating a port trunk do not connect the cable of the trunk to the switch until you have configured the trunk using the management software Connecting the trunk cables to the switch before you have confi...

Page 30: ......

Page 31: ...outlet has power by connecting another device to it Try connecting the unit to another power source Try using another power cord If a LINK ACT LED is OFF do the following Check that the end node conn...

Page 32: ...straight through RS 232 cable Do not use a cross over cable Check to be sure that the operating parameters on the terminal or terminal emulation program if you are using a PC have been set correctly R...

Page 33: ...m x 41 mm 17 32 in x 6 85 in x 1 61 in Weight AT FS7016 1 5 kg 3 30 lb AT FS7024 2 26 kg 4 98 lb Environmental Maximum Operating 0 to 40 C 32 to 104 F Maximum Storage 25 to 70 C 13 F to 158 F Relative...

Page 34: ...T FS7016 100 240 V AC 0 8A 50 60 Hz AT FS7924 100 240 V AC 0 5A 50 60 Hz Power Consumption 27W maximum Agency Compliance EMI RFI FCC Class A EN55022 Class A EN6100 3 2 EN6100 3 3 VCCI Class A CISPR 22...

Page 35: ...ts of the RJ 45 connector Figure 12 RJ 45 Connector Table 4 lists the 10 100Base TX connector pins and their signals when the port is operating in either MDI or MDI X configuration Table 4 RJ 45 Pin S...

Page 36: ......

Page 37: ...xe contient la traduction en plusieurs langues des instructions de s curit figurant dans ce guide T rke T m liite sis lt t ss oppaassa esiintyv t turvaohjeet usealla kielell Importante questa appendic...

Page 38: ...outlet should be installed near the equipment and should be easily accessible U S Federal Communications Commission Radiated Energy Note This equipment has been tested and found to comply with the li...

Page 39: ...55024 4 Elektrische Sicherheit TUV EN60950 UL60950 cULus Sicherheit 5 Achtung Gef hrliche Spannung Das Geh use nicht ffnen Das Ger t enth lt keine vom Benutzer wartbaren Teile Das Ger t steht unter Ho...

Page 40: ...en elektriske str m til produktet f r LAN kablerne monteres eller afmonteres 6 Fare Under Uvejr Fare UNDLAD at arbejde p udstyr eller KABLER i perioder med LYNAKTIVITET Installation 7 Advarsel Den str...

Page 41: ...estellen of KABELS WERKEN bij BLIKSEM Installatie 7 Waarschuwing Het toestel wordt uitgeschakeld door de stroomkabel te ontkoppelen Om het toestel stroomloos te maken de stroomkabel ontkoppelen 8 Aan...

Page 42: ...IER le mat riel ou les C BLES lors d activit orageuse Installation 7 Attention Le cordon d alimentation sert de mise hors circuit Pour couper l alimentation du mat riel d brancher le cordon 8 Equipeme...

Page 43: ...alamaniskuvaara Hengenvaara L TY SKENTELE laitteiden tai KAAPELEIDEN KANSSA SALAMOINNIN AIKANA Asennus 7 Huomautus Virtajohtoa k ytet n virrankatkaisulaitteena Virta katkaistaan irrottamalla virtajoht...

Page 44: ...rante PRECIPITAZIONI TEMPORALESCHE Installazione 7 Attenzione Il cavo di alimentazione usato come dispositivo di disattivazione Per togliere la corrente al dispositivo staccare il cavo di alimentazion...

Page 45: ...edslag Fare ARBEID IKKE p utstyr eller KABLER i TORDENV R Installasjon 7 Forsiktig Str mledningen brukes til frakoble utstyret For deaktivisere utstyret m str mforsyningen kobles fra 8 Utstyr For Stik...

Page 46: ...OS durante per odos suscet veis a QUEDAS DE RAIO Instala o 7 Cuidado O cabo de alimenta o utilizado como um dispositivo de desconex o Para deseletrificar o equipamento desconecte o cabo de alimenta o...

Page 47: ...quipos o en LOS CABLES durante TORMENTAS ELECTRICAS Instalacion 7 Atencion El cable de alimentacion se usa como un dispositivo de desconexion Para desactivar el equipo desconecte el cable de alimentac...

Page 48: ...kablarna vid SKV DER Installation 7 Varning N tkabeln anv nds som str mbrytare f r att koppla fr n str mmen dra ur n tkabeln 8 Utrustning Med Plugg Uttaget skall installeras i utrustningens n rhet och...

Reviews: