background image

AT-8600 Series

 

Installation & Safety Guide

AT-8624T/2M

 

AT-8624PoE

 

AT-8648T/2SP

Download the complete document set from

 

www.alliedtelesis.com/support/software

Summary of Contents for AT-8600 Series

Page 1: ...AT 8600 Series Switch Installation and Safety Guide AT 8624T 2M AT 8624PoE AT 8648T 2SP...

Page 2: ...AT 8600 Series Installation Safety Guide AT 8624T 2M AT 8624PoE AT 8648T 2SP Download the complete document set from www alliedtelesis com support software...

Page 3: ...written notice The information provided herein is subject to change without notice In no event shall Allied Telesis Inc be liable for any incidental special indirect or consequential damages whatsoeve...

Page 4: ...4 Selecting a Site 5 Installing the Switch 6 Connecting the Switch 10 Checking LEDs 13 Obtaining Documentation and Resources 18 Standards 19 Safety 20 Sicherheit 21 Sikkerhed 23 Veiligheid 24 S curit...

Page 5: ...ged or missing One AC power cord One power cord retaining clip One serial cable for connecting the switch to a terminal or PC One 19 inch rack mount kit One AT 8600 Series Installation Safety Guide wh...

Page 6: ...d earthed grounded power supply source preferably dedicated and filtered Cabling must not be exposed to sources of electrical noise such as radio transmitters broadband amplifiers power lines electric...

Page 7: ...f the PSU you need an appropriate DC power source DC supply cable ring connectors and a crimp tool Choose a suitable operating location You can install the switch either in a 19 inch rack on a flat be...

Page 8: ...eady powered on you must restart the switch before you can use the module 2 Place the switch in its operating location If installing the switch in a rack Remove the rubber feet on the bottom of the sw...

Page 9: ...l main power supply that functions from100 240 VAC and 50 60 Hz Specific power supply requirements for the model are on the rear or underside of the switch If the supply is outside the acceptable rang...

Page 10: ...h cable connection is secure The switch can now process basic Layer 2 switching functions 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 FAULT RPS MASTER PWR MODE 1 3 5 7 9 11 2 4 6 8...

Page 11: ...ters on your terminal or terminal emulation program to Bit rate 9600 Data bits 8 Parity None Stop bits 1 Flow control None 3 Log in After the switch has booted the login prompt appears If it does not...

Page 12: ...h letters to uniquely match the desired one press the Tab key 7 Save the configuration Save your configuration to a new file by using the command create config filename cfg Then set the switch to load...

Page 13: ...able IP enable ip 5 Assign the vlan1 interface an IP address in the same subnet as the PC add ip interface vlan1 ip ipaddress mask mask 6 Save the configuration and set the switch to use it on bootup...

Page 14: ...fan has failed 3 flashes The main PSU has failed and the RPS is now providing power 4 flashes The RPS Monitor is set to ON and the RPS is not functioning either because it has failed or has been switc...

Page 15: ...COL Off No data collisions are occurring on the port Flashing Green Data collisions are occurring on the port Mode 100 Off The port is operating at 10 Mbps Green The port is operating at 100 Mbps Mode...

Page 16: ...ode LEDs Bottom LED Off Either DC Mode or PoE Mode D C Mode Off There is no link between the port and the end node Green The port is operating in full duplex mode Red The port is operating in half dup...

Page 17: ...and the end node Mode COL Off No data collisions are occurring on the port Flashing Green Data collisions are occurring on the port Mode SPD Off The port is operating at 10 Mbps Green The port is oper...

Page 18: ...port and the end node Mode COL Off No data collisions are occurring on the port Flashing Green Data collisions are occurring on the port Mode SPD Off The port is operating at 10 100 Mbps Green The por...

Page 19: ...ort software You need Adobe Acrobat Reader software to view search or print these documents You can download it from www adobe com Other resources How To Notes describe a range of standard Allied Tele...

Page 20: ...signed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and...

Page 21: ...D AS A DISCONNECTION DEVICE TO DE ENERGIZE EQUIPMENT disconnect the power cord ELECTRICAL TYPE CLASS 1 EQUIPMENT THIS EQUIPMENT MUST BE EARTHED Power plug must be connected to a properly wired earth g...

Page 22: ...uipment must be contained in the same building including the interconnected equipment s associated LAN connections CAUTION The surface mount fuses F1 to F24 on the Power over Ethernet daughterboard in...

Page 23: ...einer Umgebungstemperatur von nicht mehr als 40 C entworfen NETZSICHERUNG Bei der Installation mu der auf dem Typenschild angezeigte Nennwert des Ger tes f r den Anschlu an das Netz beachtet werden VO...

Page 24: ...ATET AFBRYDES tages ledningen ud af stikket ELEKTRISK KLASSE 1 UDSTYR DETTE UDSTYR KR VER JORDFORBINDELSE Stikket skal v re forbundet med en korrekt installeret jordforbunden stikkontakt En ukorrekt i...

Page 25: ...nde ELEKTRISCHE schokken te voorkomen Binnenin bevinden zich geen onderdelen die door de gebruiker onderhouden kunnen worden Dit toestel staat onder GEVAARLIJKE SPANNING en mag alleen worden geopend d...

Page 26: ...gelijkwaardig door de fabrikant aanbevolen type ALLE LANDEN het toestel installeren overeenkomstig de lokale en nationale elektrische voorschriften S curit MISE EN GARDE dans un environnement domestiq...

Page 27: ...e en compte la somme des puissances indiqu es sur les tiquettes au moment de connecter le mat riel une source de courant alternatif ATTENTION R PARTITION DE LA CHARGE M CANIQUE Le montage du mat riel...

Page 28: ...on asennettava laitteen l helle ja siihen on oltava esteet n p sy HUOMAUTUS Ilmavaihtoreiki ei pid tukkia ja niill t ytyy olla vapaa yhteys ymp r iv n huoneilmaan jotta ilmanvaihto tapahtuisi K YTT L...

Page 29: ...OGLIERE LA CORRENTE AL DISPOSITIVO staccare il cavo di alimentazione ELETTRICIT DISPOSITIVI DI CLASSE 1 QUESTO DISPOSITIVO DEVE AVERE LA MESSA A TERRA La spina deve essere inserita in una presa di cor...

Page 30: ...n produktet for rsake radioforstyrrelse Hvis dette skjer m brukeren ta de n dvendige forholdsregler ADVARSEL Laserprodukt av klasse 1 ADVARSAL Stirr ikke p str len ELEKTRISITET ADVARSEL FARE FOR ELEKT...

Page 31: ...anten Batteriene m kasseres i samsvar med fabrikantens instruksjoner ALLE LAND Produktet m installeres i samsvar med de lokale og nasjonale elektriske koder Seguran a AVISO Num ambiente dom stico este...

Page 32: ...eratura ambiente m xima de 40 graus cent grados EL TRICO SOBRECARGA DA REDE DE CORRENTE ALTERNADA AC Antes de instalar o produto verifique o efeito cumulativo da conex o de diversos aparelhos rede de...

Page 33: ...POSITIVO DE DESCONEXION PARA DESACTIVAR EL EQUIPO desconecte el cable de alimentaci n ELECTRICO EQUIPO DEL TIPO CLASE 1 ESTE EQUIPO TIENE QUE TENER CONEXION A TIERRA El cable tiene que conectarse a un...

Page 34: ...klass 1 VARNING Laserstr lning n r enheten r ppen TILLK NNAGIVANDEN BETR FFANDE ELEKTRICITETSRISK RISK F R ELEKTRISK ST TF r att undvika ELEKTRISK st t ta ej av locket Det finns inga delar inuti som b...

Page 35: ...MEKANISK BELASTNING Utrustningen ska installeras i chassit p s s tt att fara inte uppst r p g a oj mn belastning Litium batteri F r endast bytas av utbildade och kvalificerade tekniker VARNING Risk f...

Reviews: