© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Maintenance
91
70457901ENR7
8. Immediately remove and weigh the load. Refer to
Table 18
for acceptable weight range. If less than
minimum pounds indicated in
Table 18
, the fire
suppression system has failed the maintenance
test. Refer to the
Troubleshooting
section
.
IMPORTANT: If the fire suppression system failed
the maintenance test, DO NOT operate the tumble
dryer.
9. Clean up any water on the floor.
10. Lock the fire suppression system control box.
11. If the separate alarm option is being used,
reconnect the auxiliary alarm output.
12. Start the tumble dryer to dry the test load.
13. On maintenance record, check box if fire
suppression system passed the test, date and sign
record.
Figure 62
Dry Weight
Wet Weight
Minimum
Weight
lbs.
kg
lbs.
kg
lbs.
kg
50
25
11
40-44
18-20
35
16
75
40
18
57-61
26-28
52
24
Table 18
TMB2010N
1
Spray Manifold
2
Water Spray
TMB2010N
1
2