Installation
F232160
16
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation Instructions
To activate lubricator:
Using a screwdriver or other
object, tighten activating screw until plastic ring top
breaks away from screw body. This will ensure proper
seal of screw and pressure chamber; it is also a safety
feature to prevent removal of screw.
Mounting:
All fittings or grease lines should be
precharged using hand grease gun on first installation
of Perma lubricators. This step need not be repeated
when replacing Perma.
Perma lubricators are made with a 1/4 inch NPT. In
cases where grease fittings have a smaller or larger
thread size, use standard plumbing adapters.
Perma lubricators require about 30 hours to develop
operating pressure. In those applications where
completely uninterrupted lubrication is required,
Perma should be activated in advance of installation.
Figure 10
PHM537N
PHM537N
Contains Potassium Hydroxide (caustic)
under pressure. Do not open, puncture or
remove activating screw. In case of
accidental breakage and exposure of liquid
to skin or eyes flush with water for
15 minutes. If exposed to eyes, contact
physician after flushing with water. Do not
expose to temperatures over 150°F (83°C).
W453
CAUTION