43. COIN DROP
a. Removal:
(1) Unlock control panel. Refer to
Figure 17,
Step 1
.
(2) Pull top of control panel away from control
cabinet far enough to allow lifting control
panel up and off the rail support of the
control cabinet front. Refer to
Figure 17,
Step 2
.
(3) Remove control panel away from control
cabinet as far as wires permit. Refer to
Figure 17, Step 3
.
(4) Remove 2 screws holding front of cabinet
top to top front edge of control cabinet
front. Refer to
Figure 19
.
(5) If area or space permits, lift cabinet top to
a vertical position by hinging it on the rear
hinges.
NOTE: To avoid damage to hinges, be sure to
support cabinet top with a small chain or something
similar. Refer to
Figure 21
.
(6) If equipped with security top panel,
remove screws and carriage bolt holding
panel to control cabinet front. Refer to
Figure 21
. Slide security top panel back
just far enough to disengage tabs on panel
from control cabinet front and remove
security panel. Refer to
Figure 21
.
(7) Disconnect coin drop harness at disconnect
block.
(8) Use a 3/8 inch square drive socket, with
number 310P4–quarter inch Ratchet
Extension Tool, to remove 2 locknuts
holding coin drop to front of control
cabinet.
NOTE: A 3/8 inch square drive socket, size 7/16
inch, fits over end of the 310P4 Extension Tool. A
1/4 inch ratchet fits in the other end. Refer to
Figure 22
.
(9) Lift back end of coin drop and pull drop
straight back until front edge of the drop’s
front face plate clears the 2 guide wires.
(10) Carefully slide drop straight back until
drop clears inside wall of control cabinet.
Carefully remove drop out through top of
control cabinet.
Figure 21
3
2
1
FLW1654S
SECURITY
PANEL
CABINET
TOP
WIRE, ROPE
OR CHAIN
SCREWS
CARRIAGE
BOLT
NUT