37987
47
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
TUB COVER AND GASKET
NOTE: When installing outer tub cover, always use
a new cover gasket.
NOTE: Clean and remove any foreign material in
gasket groove of outer tub cover and outer tub
flange.
a. Starting at the positioning tab located between
the two bleach funnel outlet tabs, lay gasket
into gasket groove of tub cover. Refer to
Figure 33.
b. Using your fingers, press gasket down into
gasket groove of tub cover. Avoid pressing
gasket past ends of hold-down tabs.
IMPORTANT: Care must be taken not to twist or
bunch gasket in any one area to avoid leaks after
assembly.
c. Install gasket past ends of hold-down tabs to
bottom of gasket groove using semi-curled end
of tub cover tool Part No. 273P4.
NOTE: Tub cover tool Part No. 273P4 is designed to
spread open hold-down tabs to prevent tearing of
gasket during installation.
d. With tub cover tilted at approximately a 45
degree angle, insert positioning pin into notch
on outer tub flange. Refer to Figure 34.
NOTE: Two bleach funnel outlet tabs must be
angled downward toward inside wall of outer tub
for proper dispensing of bleach.
e. Lower cover and push down firmly on top of
hold-down tabs next to positioning pin until
tabs snap over edge of outer tub flange.
f. Cross over to opposite side of tub cover and
push down firmly on top of hold-down tabs
until tabs snap over edge of outer tub flange.
Continue with this criss-cross pattern, until tub
cover is fully seated. Visually check each tab
area again to ensure cover is seated.
g. Check whether or not bleach drain tabs are in
the down position by looking through the
square holes in bleach funnel area of tub cover.
If tabs are not down, a small screwdriver can be
inserted down through holes in bleach funnel
area to straighten tabs.
h. Reinstall filler hose on outer tub cover.
NOTE: When reinstalling filler hose, the white line
on hose that connects to tub cover must be aligned
with line located on top side of outer tub cover.
Refer to Figure 32.
i. Place agitator on top of drive bell. Slowly rotate
agitator until fingers on underside of agitator
line up with large slots on drive bell.
j. A sharp blow on top of agitator, with palm of
your hand, will force agitator down onto drive
bell, allowing fingers on underside of agitator
to lock under bottom edge of drive bell.
NOTE: Do not push agitator onto drive bell any
further than necessary.
k. Reinstall cabinet top and secure to washer
cabinet using screws previously removed.
l. Reinstall front panel.
39. OUTER TUB
a. Open loading door.
b. Remove agitator by placing two agitator hooks,
No. 254P4P, under bottom edge of agitator.
Refer to Figure 12.
IMPORTANT: Hooks should be positioned 180
degrees of each other, and must be placed under
agitator vane for greater stability. If hooks are
placed between vane area, agitator damage may
occur.
c. Using a rocking motion (back and forth)
carefully lift agitator off drive bell.
d. Remove two screws from bottom edge of front
e. Pull bottom of panel away from washer until
hold-down clips (located on top flange of
panel) disengage from slots in cabinet top.
Refer to Figure 25.