36
505894
Section 5 Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
23. DRIVE MOTOR
Refer to
Figure 5
.
a. Remove motor and exhaust assembly. Refer to
Paragraph 51
.
b. Disconnect motor wire harness at motor
disconnect block.
NOTE: Refer to wiring schematic, Section 8, for
internal motor switch wires.
NOTE: Drive Motor Resistance
120 Volt
2,460 – 3,100 Ohms
240 Volt
10,000 - 13,000 Ohms
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
Figure 5
2
6
4
3
5
1
G
DRIVE
MOTOR
MOTOR AND
EXHAUST
ASSEMBLY
D326SE3A
1
2
4
6
5
3
MOTOR
DISCONNECT
BLOCK
MOTOR
SWITCH