Electrical Requirements
43
70420301 (EN)
To Connect Electrical Service To
The Tumble Dryer
The following steps outline the procedure for
connecting the electrical service to the tumble dryer.
NOTE: The wiring diagram is located in the
junction box.
1. Install a circuit breaker as close to the tumble
dryer as possible. If more than one tumble dryer
is being installed, a circuit breaker should be
provided for each. This will make it possible to
disconnect each tumble dryer for maintenance
purposes.
2. Connect the conduit-encased leads to the circuit
breaker. Connect the wire leads to the appropriate
labeled terminal on the terminal block. The
ground wire must be connected to the ground
connection as shown in
3. Check the electrical service phase sequence
(three phase only) as follows:
a. Energize the electrical service (on reversing
tumble dryers, ensure nonreversing is
selected) and momentarily start the tumble
dryer. Check the direction of the cylinder
rotation. If the cylinder rotates clockwise
(viewed from the front), the phase sequence is
correct. If the cylinder rotates
counterclockwise, proceed with step b.
NOTE: When viewed from the front, the
fan should rotate clockwise on 50 and 75
pound models and counterclockwise on F75
models.
b. Disconnect and reverse any two service leads
on the terminal block (example: switch L2
and L3 on terminal block).