Section 6
Test Procedures
IMPORTANT: Electrical test procedures in this
service manual are performed by using a Volt-Ohm
meter. Tests can also be performed using a multi-
meter or any other electrical testing equipment with
which the service person is familiar.
20. TIMER CONTACTS
.
a. Disconnect wires from timer, except timer
motor wires.
NOTE: Refer to appropriate wiring diagram when
rewiring timer.
b. Manually rotate timer out of “OFF” position
and into cycle.
c. Set test meter to read Ohms. The following
readings should be found:
(1) Motor circuit test – L1 and M = “zero”
Ohms (closed)
(2) Heat circuit test – L2 and H = “zero” Ohms
(closed)
(3) Timer motor test – approximately 2462-
2714 Ohms or apply live power to timer
motor terminals and motor should run.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
DRY1827S
ELECTRIC MODELS WITH C OR T IN
12
TH
POSITION OF MODEL NUMBER
DRY1826S
ALL OTHER MODELS
Figure 3
MOD
60-1
XXX VAC
RSPC
MODEL 275BEF
3 WATT
KI
NGSTON
TM
No.
L2
L2
T
A
L3
R
M
L1
P/B
P/B
S
H
N
Timer Motor
Wires
“M”
“L1”
“L2”
“H”
MOD
60-1
XXX VAC
RSPC
MODEL 275BEF
3 WATT
KI
NGSTON
TM
No.
L2
L2
T
A
L3
R
M
L1
P/B
P/B
S
H
N
Timer Motor
Wires
“M”
“L1”
“L2”
“H”