24
39201
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
f. CONTROL PANEL OVERLAY
(Removal):
(1) Remove control panel attaching screws.
Refer to Figure 5. Lay assembly forward on
protective pad on cabinet top.
(2) Loosen setscrews holding switch knobs to
switch shafts. Refer to Figure 7.
(3) Remove knurled nuts holding switches to
control panel. Refer to Figure 7.
NOTE: Lockwashers must be between switches and
control panel when installing switches. Refer to
Figure 7.
(4) Disconnect wires from switches and
indicator lights.
NOTE: Refer to appropriate wiring diagram when
rewiring switches and indicator lights.
(5) Remove control panel overlay by peeling it
from control panel frame.
NOTE: Control panel overlay has an adhesive
backing.
g. CONTROL PANEL OVERLAY
(Installation):
NOTE: Before removing protective backing from
new overlay, check fit of overlay to control panel
frame. Switch holes are the locating guides.
(1) Once panel overlay is fitted to the front of
control panel frame, carefully peel
protective backing from the left end of
panel overlay and press into place.
(2) Remove rest of protective backing from
panel overlay and firmly press overlay into
place on control panel frame.
22. TIMER ASSEMBLY
a. TIMER REMOVAL (Metered Models):
NOTE: DO NOT attempt to repair timer.
(1) Unlock and remove meter case service
door.
(2) Remove timer bracket cap screw. Refer to
(3) Slide timer and bracket toward rear of
meter case to disengage bracket from
shoulder screw. Lift timer and bracket out
of meter case through service door opening
as far as wires will permit.
NOTE: If only replacing clutch, proceed to step 7.
(4) Disengage wire harness terminal block plug
from timer by pressing in movable locking
tabs (located on each side of terminal block
plug). Refer to Figure 10. Then pull
terminal block plug away from timer.
(5) Disconnect ground wire from terminal on
timer. Refer to Figure 10.
IMPORTANT: To avoid an open circuit, DO NOT
pull on terminal block wires when removing block
from timer as this could damage wires or terminal
crimpings. Before attaching wire harness terminal
blocks to timer, be sure all male terminals on timer
are straight and are capable of accepting terminals
from wire harness terminal blocks.
Figure 9
TIMER
BRACKET
METER
CASE
W334SE1A
METER
CASE
CAP
SCREW
TIMER
SHOULDER
SCREW