39201
21
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 5
Service Procedures
IMPORTANT: When reference is made to
directions (right or left) in this manual, it is from
operator’s position facing front of washer.
21. CONTROL HOOD ASSEMBLY
a. CONTROL PANEL:
(1) Remove two control panel attaching
screws. Refer to Figure 5. Lay assembly
forward on a protective pad on cabinet top.
(2) Unplug wire harness quick disconnect
blocks, two ground wires and leads from
pressure switch and loading door switch.
Refer to Figure 6.
NOTE: Refer to appropriate wiring diagram when
reconnecting wire harnesses, ground and switch
leads.
Figure 5
W491SE1A
PANEL ATTACHING
SCREW
Figure 6
W489SE3B
GROUND
WIRES
GROUND
WIRES
DISCONNECT
BLOCKS
PRESSURE
SWITCH
DISCONNECT
BLOCKS
INDICATOR
LIGHT
PRESSURE
HOSE