F8208801
52
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Error Codes
Following is a list of possible error codes for an
electronic control. Errors beginning with “EI” refer to
external device Infra-red communication errors. All
other errors refer to machine errors.
Display
Description
Cause/Corrective Action
EI01
Transmission Failure
Communication failure. Re-aim external device and try again.
EI02
Time-out Error
Communication failure. Re-aim external device and try again.
EI03
Invalid Command Code
Communication successful, but the command was not valid
for this machine type, or the control could not perform the
command in its current mode of operation. Ensure data is for
current machine type and control is in correct mode.
EI04
Expecting Upload Request
Communication failure. Re-aim external device and try again.
EI05
Invalid or Out-of-Range Data
The value in at least one of the programming options is
invalid or out of range. Recheck the programming option’s
value and try again.
EI09
CRC-16 Error
Communication failure. Re-aim external device and try again.
EI0A
Framing Error
Communication error. Re-aim external device and try again.
EI0C
Time-out Exceeded
Communication error. Re-aim external device and try again.
EI0E
Encryption Error
Communication error. Re-aim external device and try again.
If the problem persists, check that the security code is correct.
EI0F
Infra-red Disabled
Communication failure or infra-red is disabled. Manually
enable infra-red on control or re-aim external device and try
again.
E FL
Fill Error
Programmed water level not reached within 10 minutes (or
other programmed length of time) in any fill agitate cycle.
End cycle. Power down machine to clear.
E SP
SPI Communications Error
Front End control cannot communicate with output board.
Power down the machine, power up and try again.
E dL
Door Lock Error
Door does not lock immeadiately upon closing (open and
reclose door) or doesn’t unlock 5 seconds after cycle
completion. Power down machine and retry.
E do
Door Open Error
Control detects door open. Caused by pulling on door while
locked or about to lock. Correct inoperative door locking
system. End cycle. Power down machine to clear.
E Ub
Unbalance Error
Unable to balance load. Redistribute load and run cycle.
door
Door Open Indicator
Door is not closed in Start Mode. If door is closed, check for
improper wiring or faulty door switch.
Table 17 (continued)
Summary of Contents for UWL035K12
Page 2: ......