Alliance Laundry Systems UF18PC Operation/Programming Manual Download Page 21

19

Operation

F232061

Stop Routine

When the wash cycle concludes, the computer 
goes into the stop routine. The stop routine 
consists of a brief countdown and a brief 
reversing sequence, after which the computer 
will display “donE.”

If no water level is detected, and no rotation is 
detected from the AC drive, the computer will 
unlock the door and sound the buzzer for five 
seconds. The computer will display “dONE” 
for 25 seconds regardless of whether or not the 
door is opened.

If the computer cannot unlock the door, it will 
display “----” while attempting to unlock the 
door five additional times. If it is still unable to 
unlock the door after five attempts, it will flash 
“CANt”/“OPEN.” No further attempts will be 
made to unlock the door. 

Balance Detection

All models come equipped with an inverter 
drive balance detection system. 

Load balance is detected by the inverter drive 
during the drain step. The V-series computer 
will make up to seven attempts to balance the 
load during a drain step. 

The computer begins monitoring the balance 
signal from the AC inverter drive eight seconds 
after the water level drops below low level. If 
the balance signal indicates that the wash load 
is evenly distributed, the computer will start 
the spin step.

If the balance signal indicates that the wash 
load is unbalanced, the computer will slow 
the cylinder down to wash speed for seven 
seconds in an attempt to redistribute the load. 
The computer will make as many as seven 
attempts, if needed.

If on the seventh attempt the load is not 
balanced, the machine will light the out-of-
balance LED indicator located in the upper left 
corner of the display (to the left of the first 
digit) until the next drain step. The machine 
will then skip the programmed spin and 
continue to the next programmed step.

If this occurs in the final segment, the machine 
will begin the Stop routine.

Overtravel Limit Switch

As a fail-safe measure, an overtravel limit 
switch is installed. The limit switch serves to 
trigger a rapid stop. This means that if the 
machine balance “passes” the inverter drive 
balance detection system at the drain step but 
the balance switch detects an out-of-balance 
load condition at the extract step, the basket 
will brake to a rapid stop.

To reset the control, push the stop button and 
open the door when the display shows “donE.”

Test Cycle

A test cycle is provided as a means of verifying 
proper machine operation. Before the test 
cycle is run, it must be enabled. Refer to the 
Programming section of this manual for 
instructions on enabling and running the 
test cycle.

NEVER insert hands or objects into basket 
until it has completely stopped. Doing so 
could result in serious injury.

SW012

WARNING

Summary of Contents for UF18PC

Page 1: ...ure Reference If this machine changes ownership this manual must accompany machine Operation Programming R2 Washer Extractor Cabinet Freestanding Variable Speed Instructions for Operating and Programm...

Page 2: ......

Page 3: ...15 Start Up 16 Opening Door 16 Loading 16 Supply Dispenser 16 Cycle Selection 17 Cycle Execution 17 Fill 17 Wash 18 Drain 18 Spin 18 Stop Routine 19 Balance Detection 19 Overtravel Limit Switch 19 Tes...

Page 4: ...32061 2 Copyright 1999 Alliance Laundry Systems LLC All rights reserved No part of this book may be reproduced or transmitted in any form or by any means without the written permission of the publishe...

Page 5: ...qualified personnel familiar with electrical test procedures test equipment and safety precautions should attempt adjustments and troubleshooting Disconnect power from the machine before removing the...

Page 6: ...arning symbol indicates the presence of hot surfaces that could cause serious burns Stainless steel and steam lines can become extremely hot and should not be touched This warning symbol indicates the...

Page 7: ...e door without locking it and attempt to start the machine The machine should not start with the door unlocked c Close and lock the door and start a cycle Attempt to open the door while the cycle is i...

Page 8: ...use safety hazards external to the machine in conjunction with adjacent electrical equipment Ventilation The need for make up air openings for such laundry room accessories as dryers ironers water hea...

Page 9: ...125 psi 8 5 bar may result in damage to steam components and may cause personal injury For machines equipped with optional steam heat install piping in accordance with approved commercial steam pract...

Page 10: ...an cause the AC inverter drive to generate nuisance errors If voltage is above 230V for 200V installations or above 440V for 400V installations a buckboost transformer is recommended If voltage is abo...

Page 11: ...All information illustrations and specifications contained in this manual are based on the latest product information available at the time of printing We reserve the right to make changes at any tim...

Page 12: ...ation 10 F232061 Figure 1 MA019K Supply Dispenser V Computer Keypad Coin Meter Door Handle Door Unlock Button Door Control Panel Top Cover Outer Front Panel Door Glass Inner Front Panel Front View MA0...

Page 13: ...11 Operation F232061 Figure 2 MA018K AC Drive Cooling Fan Filter Power Connection Cold Water Inlet Hot Water Inlet Steam Inlet Optional Vent Drain Outlet Rear Panel Vacuum Breaker Rear View MA018K...

Page 14: ...ter drive control which provides four motor speeds using a single motor The solid state output board converts motor logic from the V computer to the correct signals for the AC inverter drive The AC in...

Page 15: ...when the machine is in RUN mode Medium Water Level High Water Level Out of Balance Condition Low Water Level Keypad Key Description Up Used in cycle selection pressing this key moves among cycles fro...

Page 16: ...wing the final unsuccessful attempt Water level The computer attempts to maintain the water level programmed for the fill preceding the agitation step If the level falls below the programmed level the...

Page 17: ...n SETUP mode SdLY Spin coast delay Con1 deno Coin 1 value flashes briefly before showing value of coin 1 in SETUP mode STOP Stop routine donE Cycle and stop routine have ended Con2 deno Coin 2 value f...

Page 18: ...chemicals and cause greater machine wear than full loads Partial loads also increase the possibility of a severe out of balance condition When loading is complete ensure that all fabric is inside the...

Page 19: ...art key Note The computer does not count down the remaining cycle time during fills and drains or prior to first achieving the programmed heat temperature when heating The computer resumes counting do...

Page 20: ...tact a qualified service technician Spin Spin steps for all segments except Fill 6 are low speed spins These spin steps are called intermediate spins For cycles 1 14 the spin step for the Fill 6 segme...

Page 21: ...balance signal indicates that the wash load is unbalanced the computer will slow the cylinder down to wash speed for seven seconds in an attempt to redistribute the load The computer will make as many...

Page 22: ...20 NOTES F232061 Operation...

Page 23: ...Start key acts as an enter key in program mode Use this key to enter data and move to the next function in the cycle Stop The Stop key saves all data and terminates the programming procedure If it is...

Page 24: ...e following conditions are true A nonzero heat temperature is programmed The computer senses that the present temperature is below the programmed target temperature At least a low water level is prese...

Page 25: ...is showing the temperature in the sump The display will show a two digit number indicating how many cycles have been run to completion cycles which were stopped in progress are not counted Press the...

Page 26: ...key to select the desired fill level See the table below 6 Press the Start key 7 Use the Up or Down key to select the desired supply option See the table below Note If as supply 2 SUP2 step is progra...

Page 27: ...of coins and press the Start key The test cycle is as follows a Once the Start key is pressed the door interlock engages the drain valve closes the cylinder begins agitating at wash speed and both wat...

Page 28: ...is operated at distribution balancing speed j When the drain opens the three dots above the three right display digits should go off indicating that the water is draining k The computer will attempt t...

Page 29: ...L CFIL bFIL or AFIL Select HFIL hot fill CFIL cold fill bFIL warm fill or AFIL auxiliary fill LO ned or HI Select fill level LO low ned medium or HI high water level SUP0 SUP6 Select supply 0 6 0 for...

Page 30: ...or AFIL Select HFIL hot fill CFIL cold fill bFIL warm fill or AFIL auxiliary fill LO ned or HI Select fill level LO low ned medium or HI high water level SUP0 SUP6 Select supply 0 6 0 for no supply 00...

Page 31: ...IL bFIL or AFIL Select HFIL hot fill CFIL cold fill bFIL warm fill or AFIL auxiliary fill LO ned or HI Select fill level LO low ned medium or HI high water level SUP0 SUP6 Select supply 0 6 0 for no s...

Page 32: ...r Hot Warm Cold Cold Warm Level Low Low Low High Low Supply 1 2 1 2 1 2 1 2 1 2 Temp F 0 0 0 0 0 Spin Sec 0 0 0 0 0 Fill 1 Time Min 4 4 4 4 4 Water Warm Warm Cold Cold Warm Level High High High High H...

Page 33: ...Cold Cold Cold Cold Cold Level Low Low Low High Low Supply 3 3 3 3 3 Temp F 0 0 0 0 0 Spin Min 4 4 4 2 2 Total Cycle Time Does not include fill drain time 17 17 17 13 15 Approximate Water Usage Gallo...

Page 34: ...ot Warm Cold Cold Warm Level Low Low Low High High Supply 1 2 1 2 1 2 1 2 2 Temp F 0 0 0 0 0 Spin Sec 0 0 0 0 0 Fill 1 Time Min 4 4 4 2 2 Water Warm Warm Cold Cold Cold Level High High High High High...

Page 35: ...Cold Cold Cold Cold Cold Level Low Low Low High High Supply 3 3 3 3 3 Temp F 0 0 0 0 0 Spin Min 4 4 4 5 5 Total Cycle Time Does not include fill drain time 21 21 21 17 23 Approximate Water Usage Gallo...

Page 36: ...34 NOTES F232061 Programming...

Page 37: ...gurese de que este manual vaya con la misma Operaci n y programaci n R2 Lavadora extractora de gabinete autoestable y velocidad variable Instrucciones para la operaci n y la programaci n de la microco...

Page 38: ......

Page 39: ...Surtidor de suministros 54 Selecci n de ciclos 55 Ejecuci n de un ciclo 55 Llenado 55 Lavado 56 Desag e 56 Centrifugado 57 Rutina de paro 57 Detecci n de balance 57 Interruptor de l mite de sobrecarre...

Page 40: ...pyright 1999 Alliance Laundry Systems LLC Todos los derechos reservados Se prohibe reproducir o transmitir en cualquier forma o por cualquier medio cualquier parte de este libro sin el permiso por esc...

Page 41: ...motor S lo el personal capacitado para realizar procedimientos de pruebas el ctricas y conocedor del equipo de pruebas y de las precauciones de seguridad debe intentar hacer ajustes y reparar aver as...

Page 42: ...eben tomarse precauciones adecuadas al manejar materiales corrosivos o c usticos Este s mbolo de advertencia indica que existen superficies calientes que podr an causar graves quemaduras El acero inox...

Page 43: ...ta est abierta b Cierra la puerta sin ponerle el seguro e intente arrancar la m quina La m quina no debe arrancar si la puerta no est asegurada c Cierre y ponga el seguro a la puerta y comience el cic...

Page 44: ...otores fallen y puede accionar el interruptor de falla en la conexi n a tierra Tambi n pueden presentarse problemas de corrosi n en algunos componentes met licos de la m quina Si la humedad relativa e...

Page 45: ...tes pueden fallar y pueden ocasionarse graves lesiones personales Presi n de vapor opcional Se obtiene el mejor rendimiento si el vapor se suministra a una presi n entre 2 0 y 5 4 Barias 30 y 80 PSI A...

Page 46: ...te el filtro del ventilador de enfriamiento del mando inversor de CA y el mando en s Las fluctuaciones de corriente el ctrica de fuentes tales como suministros de potencia no interrumpibles UPS pueden...

Page 47: ...ca lave piezas de maquinaria o de autom viles en la m quina Esto puede da ar seriamente la canasta Nunca permita que los ni os jueguen en o cerca de esta m quina Si alg n ni o queda atrapado dentro de...

Page 48: ...46 NOTAS F232061 SP Seguridad...

Page 49: ...ciones y las especificaciones contenidas en este manual est n basadas en la informaci n m s reciente disponible al momento de impresi n Nos reservamos el derecho de hacer cambios en cualquier momento...

Page 50: ...ierta superior Surtidor de suministros Panel de control Teclado de la computadora serie V Contador de Puerta de vidrio Panel delantero externo Panel delantero interno Manija de la puerta Bot n para Pu...

Page 51: ...K Filtro del ventilador de enfriamiento del mando de CA Entrada de agua fr a Entrada de agua caliente Entrada de vapor Rel de Rejilla de Salida de desag e Panel trasero Conexi n de la Vista posterior...

Page 52: ...os de la m quina est n cubiertos en un compartimiento independiente localizado debajo de la cubierta superior de la m quina El mando inversor de CA utiliza un software especial de detecci n de balance...

Page 53: ...de RUN marcha Nivel de agua medio Nivel de agua alto Carga desbalanceada Nivel de agua bajo Teclado Tecla Descripci n Up Se usa en la selecci n de ciclos Al oprimir esta tecla se pasa de los ciclos m...

Page 54: ...perior del d gito de la pantalla indicadora situado m s a la izquierda se ilumina despu s del ltimo intento sin xito Nivel de agua La computadora intenta mantener el nivel de agua programado para el l...

Page 55: ...i n gradual de la velocidad de centrifugado Con1 deno Valor de moneda 1 destella brevemente antes de mostrar el valor de moneda 1 en la modalidad de SETUP preparaci n STOP Rutina de paro donE La rutin...

Page 56: ...ales desperdician energ a agua productos qu micos y causan un mayor desgaste en la m quina que las cargas completas Las cargas parciales tambi n aumentan la posibilidad de que se presenten situaciones...

Page 57: ...e Start arrancar el indicador mostrar alternadamente SHUT cerrar y door puerta Verifique que la puerta est correctamente cerrada y oprima una vez m s la tecla Start arrancar para iniciar el ciclo dese...

Page 58: ...usa y seguidamente repetir esta secuencia por el tiempo programado La tabla siguiente muestra los tipos de agitaci n disponibles Nota Si el agua no llega a la temperatura programada en 30 minutos la c...

Page 59: ...fija en cero la computadora se mueve al siguiente segmento del programa de ciclos Si el segmento est el final de un programa de ciclo la computadora pasa a la rutina de paro Rutina de paro Cuando se...

Page 60: ...sag e siguiente La maquina entonces se salta el paso de centrifugado programado y continua con el paso programado siguiente Si ocurre esto en el segmento final la maquina iniciara la rutina de parada...

Page 61: ...num ricos tales como tiempo o temperatura al crear f rmulas de lavado Start arrancar La tecla Start act a como una tecla de ingreso o registro Enter en la modalidad de programaci n Use esta tecla par...

Page 62: ...Cent grados Los rangos aceptables para las temperaturas programadas son de 25 C a 93 C 75 F a 200 F Calor auxiliar Calor es una salida dedicada de la computadora serie V que controla una fuente de ca...

Page 63: ...seguidamente la denominaci n de moneda correspondiente Por ejemplo si la moneda 2 es una moneda de 50 centavos la pantalla indicar 50 para la denominaci n de la moneda 2 Oprima la tecla Up arriba para...

Page 64: ...indicador de la computadora muestre el segmento a editar Oprima la tecla Start arrancar 2 Use la tecla Up arriba o la tecla Down abajo para seleccionar el tiempo de segmento deseado Establezca este v...

Page 65: ...segmento editado es el segmento final del ciclo Llenado 6 aparecer en la pantalla el n mero del ciclo Nota Cada uno de los centrifugados intermedios es seguido por un per odo de 25 segundos de dismin...

Page 66: ...llenando hasta el nivel bajo el motor produce agitaci n hacia adelante y hacia atr s y el desag e se cierra Las v lvulas de llenado se cierran cuando el agua alcanza el nivel bajo a la vez que se enci...

Page 67: ...a hasta 10 veces antes de abortar el ciclo de prueba Caso 1 Si fallan los 10 intentos de balanceo de la carga ciclo de prueba solamente la computadora apagar todas las salidas y presentar en la pantal...

Page 68: ...eleccione HFIL llenado con agua caliente CFIL llenado con agua fr a bFIL llenado con agua tibia AFIL llenado auxiliar LO ned o HI Seleccione el nivel de llenado LO bajo ned medio HI alto SUP0 SUP6 Sel...

Page 69: ...IL llenado con agua caliente CFIL llenado con agua fr a bFIL llenado con agua tibia AFIL llenado auxiliar LO ned o HI Seleccione el nivel de llenado LO bajo ned medio HI alto SUP0 SUP6 Seleccione el s...

Page 70: ...IL Seleccione HFIL llenado con agua caliente CFIL llenado con agua fr a bFIL llenado con agua tibia AFIL llenado auxiliar LO ned o HI Seleccione el nivel de llenado LO bajo ned medio HI alto SUP0 SUP6...

Page 71: ...mplado Fr o Fr o Templado Nivel Bajo Bajo Bajo Alto Bajo Prod lavand 1 y 2 1 y 2 1 y 2 1 y 2 1 y 2 Temp F 0 0 0 0 0 Centrifugado seg 0 0 0 0 0 Llenado 1 Tiempo min 4 4 4 4 4 Agua Templado Templado Fr...

Page 72: ...o Fr o Nivel Bajo Bajo Bajo Alto Bajo Prod lavand 3 3 3 3 3 Temp F 0 0 0 0 0 Centrifugado min 4 4 4 2 2 Tiempo total del ciclo No incluye el tiempo de llenado y desag e 17 17 17 13 15 Consumo aproxim...

Page 73: ...Templado Fr o Fr o Templado Nivel Bajo Bajo Bajo Alto Alto Prod lavand 1 y 2 1 y 2 1 y 2 1 y 2 2 Temp F 0 0 0 0 0 Centrifugado seg 0 0 0 0 0 Llenado 1 Tiempo min 4 4 4 2 2 Agua Templado Templado Fr o...

Page 74: ...o Fr o Fr o Nivel Bajo Bajo Bajo Alto Alto Prod lavand 3 3 3 3 3 Temp F 0 0 0 0 0 Centrifugado min 4 4 4 5 5 Tiempo total del ciclo No incluye el tiempo de llenado y desag e 21 21 21 17 23 Consumo ap...

Reviews: