Installation
510975
16
Step 4: (Electric Dryer Only) Connect
Electrical Plug
For further assistance, refer to section on
Electrical
Requirements
.
IMPORTANT: Use only a new U.L. listed No. 10
(copper wire only) three conductor power supply
cord kit rated 240 Volts (minimum), 30 Amperes
and labeled as suitable for use in a clothes dryer.
NOTE: For more detailed information on
connecting three-wire or four-wire plugs, refer to
section on
Electrical Connection
.
Four-wire cord is required for mobile homes or
where codes do not permit grounding through
neutral.
Figure 8
D275I
D006I
1
Typical Receptacle
3
Strain Relief Nut
2
Power Cord
4
Strain Relief
1
2
4
2
3
4
THREE-WIRE
1
FOUR-WIRE
3