92
801805
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
IMPORTANT: When reassembling, be sure seal on
exhaust fan cover makes airtight seal on flange of
duct. Refer to Figure 40. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted which can adversely affect dryer
performance.
IMPORTANT: When reinstalling motor and
exhaust assembly, be sure wire harness on right side
is clipped to motor mounting bracket and is routed
along dryer base (between motor mounting bracket
and right side of cabinet). Refer to Figure 41. Tab on
rear of motor mounting bracket must be slid into
slot in dryer base. Be sure the belt has been installed
on the correct side of the idler lever. Refer to
Figure 43.
j. Pull assembly forward and disengage the
middle exhaust duct.
k. Rotate the assembly 90° counterclockwise and
slide out through front of dryer.
Figure 43
Belt
Idler
Pulley
Idler
Lever
Exhaust
Duct
D247SE1A
CORRECT WAY
Belt on Wrong Side
of Idler Lever
Belt
Idler
Pulley
Idler
Lever
Exhaust
Duct
D248SE1A
INCORRECT WAY
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
WARNING
Figure 44
2
6
4
3
5
1
G
Motor
Switch
Retaining
Ring
Motor
Clamp
Motor
Pulley
Idler
Spring
Idler
Pulley
D296SE3B