800793
43
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
27. FRONT PANEL
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel. Refer to Figure 9.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
c. Model LTS85A*H only:
NOTE: Front edge of cabinet top is held in place by
two spring clips located on top flange of front panel.
Refer to Figure 10.
(1) Insert putty knife between cabinet top and
top edge of front panel (approximately
three inches in from side). Refer to
Figure 10.
(2) Push in on putty knife and at the same time
lift front edge of cabinet top. Repeat for
opposite side.
(3) If area or space permits, lift cabinet top to a
vertical position (top will rest on hinges).
NOTE: To avoid damage to hinges, be sure to
support top with a chain (not included) or
equivalent. Refer to Figure 11.
d. Using the special tool, No. 318P4, remove
dispenser drawer. Refer to Figure 12.
e. Remove two screws on top right side of front
panel (above dispenser drawer), top left two
screws and then bottom two front corner
screws. Refer to Figure 13.
f. Unplug wire harness from both the door latch
switch and from the door switch. Refer to
Figure 16. Remove clips holding wire harness
and door seal hose along top flange of front
panel and remove front panel.
Figure 11
FLW1647S
CHAIN
(continued on Page 45)